Abstract

The integrity of the blood-brain barrier (BBB), the protective barrier of the brain, is key to maintaining normal microvascular permeability and brain homeostasis. Brain microvascular endothelial cells are primary components of the blood-brain barrier. Transendothelial electrical resistance (TEER) is the electrical resistance across a cellular monolayer such as the brain microvascular endothelial cell monolayers. Measurement of TEER is considered a sensitive, reliable, and noninvasive method for evaluating barrier integrity and permeability of an endothelial cell monolayer under in vitro conditions. Measurement of TEER is also helpful for studying various cellular and molecular changes and signaling events that regulate barrier functions in endothelial monolayers. One of the in vitro endothelial cell barrier models that have been commonly used for measuring TEER is the BBB model using human or rodent brain microvascular endothelial cells grown as a monolayer. In this protocol, we describe how TEER is measured in brain microvascular endothelial cell monolayers, to determine blood-brain barrier integrity under in vitro conditions.

Keywords: Blood-brain barrier; Endothelial barrier permeability; TEER; Transendothelial electrical resistance.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Blood-Brain Barrier* / physiology
  • Brain / blood supply
  • Capillary Permeability / physiology
  • Cells, Cultured
  • Electric Impedance
  • Endothelial Cells* / physiology
  • Humans