Characterization of durability and reconnection patterns at time of repeat ablation after single-shot pulsed field pulmonary vein isolation

J Interv Card Electrophysiol. 2024 Mar;67(2):379-387. doi: 10.1007/s10840-023-01655-0. Epub 2023 Sep 30.

Abstract

Background: Pulsed field ablation (PFA) is a novel method of cardiac ablation where there is insufficient knowledge on the durability and reconnection patterns after pulmonary vein isolation (PVI). The aim of this study was to characterize the electrophysiological findings at time of repeat procedure in real-world atrial fibrillation (AF) patients.

Methods: Patients who underwent a repeat procedure (n=26) for symptomatic recurrent arrhythmias after index first-time treatment with single-shot PFA PVI (n=266) from July 2021 to June 2023 were investigated with 3D high-density mapping and ad-hoc re-ablation by radiofrequency or focal PFA.

Results: Index indication for PVI was persistent AF in 17 (65%) patients. The mean time to repeat procedure was 292 ± 119 days. Of the 26 patients (104 veins), complete durable PVI was observed in 11/26 (42%) with a durable vein isolation rate of 72/104 (69%). Two patients (8%) had all four veins reconnected. The posterior wall was durably isolated in 4/5 (80%) of the cases. The predominant arrhythmia mechanism was AF in 17/26 (65%) patients and regular atrial tachycardia (AT) in 9/26 (35%). Reconnection was observed 9/26 (35%) in right superior, 11/26 (42%) in right inferior, 7/26 (27%) in left superior, 5/26 (19%) in left inferior, p=0.31 between veins. The gaps were significantly clustered in the right-sided anterior carina compared to other regions (P=0.009).

Conclusions: Durable PVI was observed in less than half of the patients at time of repeat procedure. No significant difference in PV reconnection pattern was observed, but the gap location was preferentially located at the anterior aspects of the right-sided PVs. Predominant recurrence was AF. More data is needed to establish lesion formation and durability and AT circuits after PFA.

Keywords: Arrhythmia recurrence; Atrial fibrillation; Durability; Electrophysiology; Mapping; Pulsed field ablation; Reconduction; Reconnection; Ultra-high density.