Abstract

Objectives The aim of this study was to investigate the short-term outcomes of knotless barbed sutures used for both closures of myometrium and subcuticular tissues in patients with various operative indications and who underwent cesarean delivery (CD) in a single tertiary center. Materials and methods A retrospective cohort study was conducted, and the patients were divided into two groups. The barbed suture group consisted of patients who underwent CD using barbed sutures for uterine closure (0 Stratafix® Spiral PDS Plus, Ethicon, Somerville, NJ, USA) and subcuticular closure (4-0 Stratafix® Spiral PDS Plus). The non-barbed group consisted of patients who underwent CD using monofilament sutures for uterine closure (0-Monocryl®, Ethicon) and subcuticular closure (3-0 Opepolyx®, Alfresa, Tokyo, Japan). Results White blood cell count on post-operative day 1 was statistically lower in the barbed suture group (p=0.01), while there were no other significant differences between the two groups. Conclusion Barbed sutures can be used without major complications in patients who have undergone CD, including high-risk pregnancies.

Keywords: barbed suture; cesarean delivery; polydioxanone suture; surgical site infection; uterine closure.