Left Ventricular Assist Device: Review of Antimicrobial Prophylaxis Strategies and Incidence of Infections at a Tertiary Care Center 12-Year Experience

Open Forum Infect Dis. 2023 Sep 8;10(9):ofad465. doi: 10.1093/ofid/ofad465. eCollection 2023 Sep.

Abstract

Background: Left ventricular assist devices (LVAD) have an associated infection rate of 13%-80% postimplant. An optimal strategy for surgical infection prophylaxis (SIP) at the time of implantation has not been well defined. We aimed to evaluate the different LVAD implantation antibiotic prophylaxis regimens as well as the incidence of LVAD infection at our institution.

Methods: We performed a single-center, retrospective study of patients who underwent LVAD implantation between February 2007 and June 2019. The primary outcome was the incidence of LVAD infection (LVADI), within 3 months and 1 year of placement, between patients who received expanded or narrow-spectrum regimens for SIP. We assessed outcomes using Kaplan-Meier, time-to-first event. We used a noninferiority analysis, which was established if the narrow-spectrum event rate was no more than 5% greater than the expanded-spectrum event rate.

Results: We included 399 patients, 305 (76.4%) patients received narrow-spectrum SIP, whereas the remaining 94 (23.6%) patients received the expanded-spectrum regimen. Statistical noninferiority of the narrow spectrum to the multiple drug regimen was demonstrated at both time points, and statistical superiority of the narrow-spectrum group across 12-month follow up was further evident (P = .037).

Conclusions: We report evidence supporting noninferiority, or even superiority, of the narrow-spectrum over expanded-spectrum antimicrobial prophylaxis strategy with respect to LVADI. These findings support data-driven antimicrobial prophylaxis strategies.

Keywords: LVAD; surgical prophylaxis.