Performance of current versus modified CEUS LI-RADS in the diagnosis of non-hepatocellular carcinoma malignancies

Abdom Radiol (NY). 2023 Dec;48(12):3688-3695. doi: 10.1007/s00261-023-04043-4. Epub 2023 Sep 19.

Abstract

Purpose: The high proportion of HCC in CEUS LR-M decreases the sensitivity of LR-5 for the diagnosis of HCC. However, when modifying LR-M criteria to further improve the sensitivity of LR-5, it is also important not to compromise the diagnostic performance (especially sensitivity) of LR-M for non-hepatocellular carcinoma malignancies (non-HCCMs). The purpose of this study was to evaluate the diagnostic performance of CEUS LI-RADS (2017 version) for non-HCCMs and to explore the impact of modified CEUS LI-RADS on the diagnostic performance of LR-M.

Methods: In this retrospective study, patients with pathologically confirmed non-HCCMs were evaluated. Two radiologists independently interpreted the major CEUS features and categorized the liver lesions. New LR-M criteria were applied: early washout (< 45 s) or marked washout (< 5 min). The sensitivity values of the current and modified CEUS LR-M were assessed and then compared using a paired χ2 test. Cohen's κ was used to compare the inter-reader agreement of the LI-RADS categories.

Results: A total of 131 non-HCCMs were ultimately selected, including 71 intrahepatic cholangiocarcinomas, 26 combined hepatocellular cholangiocarcinomas, 29 metastases, and 5 other non-HCCMs. The numbers of LR-M, LR-5, LR-4, and LR-3 in liver lesions were 111, 18, 1, and 1, respectively. The inter-reader agreement of the LI-RADS categories for non-HCCMs was 0.59. The sensitivity of the current CEUS LR-M in diagnosing non-HCCMs was 84.7%. By adjusting the early washout time to < 45 s, the sensitivity of LR-M was 80.9%. By adjusting the marked washout time within 5 min, the sensitivity of LR-M was 72.5%.

Conclusion: CEUS LR-M has high sensitivity in diagnosing non-HCCMs. For LR-M nodules with nonrim arterial phase hyperenhancement and early washout, advancing the time of early washout to < 45 s has a minimal impact on the sensitivity of LR-M in diagnosing non-HCCMs compared to the condition of increasing the marked washout within 5 min.

Keywords: Contrast-enhanced ultrasound; Liver imaging reporting and data system; Non-hepatocellular carcinoma malignancies.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Bile Duct Neoplasms*
  • Bile Ducts, Intrahepatic / pathology
  • Carcinoma, Hepatocellular* / diagnostic imaging
  • Carcinoma, Hepatocellular* / pathology
  • Cholangiocarcinoma* / diagnostic imaging
  • Cholangiocarcinoma* / pathology
  • Contrast Media
  • Humans
  • Liver Neoplasms* / diagnostic imaging
  • Liver Neoplasms* / pathology
  • Magnetic Resonance Imaging
  • Retrospective Studies
  • Sensitivity and Specificity
  • Ultrasonography

Substances

  • Contrast Media