System Configuration Evaluation for a Province-Wide Clinical Information System Using the eSafety Checklist

Appl Clin Inform. 2023 Aug;14(4):735-742. doi: 10.1055/s-0043-1771392. Epub 2023 Sep 13.

Abstract

Background: According to Digital Health Canada 2013 eSafety Guidelines, an estimated one-third of patient safety incidents following implementation of clinical information systems (CISs) are technology-related. An eSafety checklist was previously developed to improve CIS safety by providing a comprehensive listing of system-agnostic, evidence-based configuration recommendations.

Objectives: We sought to use the checklist to support safe initial configuration of a provincial system-wide CIS (Alberta, Canada), referred to as Connect Care.

Methods: The checklist was applied to 13 Connect Care modules in three successive phases. First, the checklist was adapted to an abbreviated high-priority version. Second, demonstrations of each module were recorded. Finally, independent evaluation of each recording was conducted by two eSafety evaluators using the abbreviated eSafety checklist.

Results: All modules achieved greater than 72% compliance, with an average of 84%. Overall, 273 opportunities for improvement were identified, with four major areas or themes emerging: (1) inconsistent date and time, (2) unclear patient identification, (3) ineffective alert system, and (4) insufficient decision support. These opportunities were forwarded to the appropriate build teams for review and implementation.

Conclusion: This work is the first to utilize the eSafety checklist in a real-world CIS, which will become one of the largest in Canada. The checklist has shown clinical applicability in identifying gaps in CIS configuration and should be considered for use in future and pre-existing CISs.

MeSH terms

  • Canada
  • Checklist*
  • Humans
  • Information Systems
  • Patient Compliance*
  • Patient Safety