Using Protein Fingerprinting for Identifying and Discriminating Methicillin Resistant Staphylococcus aureus Isolates from Inpatient and Outpatient Clinics

Diagnostics (Basel). 2023 Aug 31;13(17):2825. doi: 10.3390/diagnostics13172825.

Abstract

In hospitals and other clinical settings, Methicillin-resistant Staphylococcus aureus (MRSA) is a particularly dangerous pathogen that can cause serious or even fatal infections. Thus, the detection and differentiation of MRSA has become an urgent matter in order to provide appropriate treatment and timely intervention in infection control. To ensure this, laboratories must have access to the most up-to-date testing methods and technology available. This study was conducted to determine whether protein fingerprinting technology could be used to identify and distinguish MRSA recovered from both inpatients and outpatients. A total of 326 S. aureus isolates were obtained from 2800 in- and outpatient samples collected from King Faisal Specialist Hospital and Research Centre in Riyadh, Saudi Arabia, from October 2018 to March 2021. For the phenotypic identification of 326 probable S. aureus cultures, microscopic analysis, Gram staining, a tube coagulase test, a Staph ID 32 API system, and a Vitek 2 Compact system were used. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), referred to as protein fingerprinting, was performed on each bacterial isolate to determine its proteomic composition. As part of the analysis, Principal Component Analysis (PCA) and a single-peak analysis of MALDI-TOF MS software were also used to distinguish between Methicillin-sensitive Staphylococcus aureus (MSSA) and MRSA. According to the results, S. aureus isolates constituted 326 out of 2800 (11.64%) based on the culture technique. The Staph ID 32 API system and Vitek 2 Compact System were able to correctly identify 262 (80.7%) and 281 (86.2%) S. aureus strains, respectively. Based on the Oxacillin Disc Diffusion Method, 197 (62.23%) of 326 isolates of S. aureus exhibited a cefoxitin inhibition zone of less than 21 mm and an oxacillin inhibition zone of less than 10 mm, and were classified as MRSA under Clinical Laboratory Standards Institute guidelines. MALDI-TOF MS was able to correctly identify 100% of all S. aureus isolates with a score value equal to or greater than 2.00. In addition, a close relationship was found between S. aureus isolates and higher peak intensities in the mass ranges of 3990 Da, 4120 Da, and 5850 Da, which were found in MRSA isolates but absent in MSSA isolates. Therefore, protein fingerprinting has the potential to be used in clinical settings to rapidly detect and differentiate MRSA isolates, allowing for more targeted treatments and improved patient outcomes.

Keywords: MALDI-TOF MS; differentiation; healthcare-associated infections; identification; methicillin-resistant Staphylococcus aureus; methicillin-sensitive Staphylococcus aureus.

Grants and funding

The Deputyship for Research and Innovation, Ministry of Education in Saudi Arabia, project no. (IFKSUOR3–083–1).