Moderate Severity SARS-CoV-2 (COVID-19) Affects Ocular Vergence Indices: Eye Tracking-Based Study

Adv Exp Med Biol. 2023:1425:325-330. doi: 10.1007/978-3-031-31986-0_31.

Abstract

Objective: Since the start of the SARS-CoV-2 (COVID-19) pandemic, it has become clear that the brain is one of the main targets for acute and chronic damage. Although neurodegenerative changes have yet to be investigated, there is already a large body of data on damage to its fiber tracts. A mobile eye tracker is possibly one of the best tools to study such damage in a COVID hospital setting. At the same time, the available data indicate that eye tracking parameters, even in healthy volunteers, demonstrate a distinct gender-specific difference.The aim of the work is to evaluate functional and structural impairments of the fiber tracts and to find possible gender-specific dynamics of eye tracking indicators in the acute period of COVID-19 pneumonia (Delta variant) of moderate severity.

Materials and methods: A single-center non-randomized retrospective study included 84 patients in the acute period of moderate severity SARS-CoV-2 (COVID-19) pneumonia (Delta variant) (Group 1). The mean time from admission was 1.4 ± 1.2 days. M:41, F:43. According to thoracic CT, the lung involvement ranged from CT 1 to CT 2. SpO2 ranged from 95% to 99%. The mean age was 35.5 ± 14.8 years (from 18 to 60). The control group (Group 2) included 158 healthy volunteers without pathology of the vision organs and central nervous system.The eye vergence index (VRx) was determined using eye tracking as a motion correlation coefficient between the angular velocities of the left and right eyeballs and was a measure of the conjugation of horizontal and vertical eye movements.The mobile complex Eye Tracker Low-Speed 20 (BVG LLC, the Netherlands) was used. Eye tracking parameters were assessed by vertical and horizontal eye vergence (VVRx and HVRx).Statistical analysis was done using the methods of parametric and non-parametric statistics.

Results: Moderate COVID-19 pneumonia resulted in a significant decrease in both VVRx and HVRx compared to controls (0.763 ± 0.127 and 0.856 ± 0.043; p < 0.000001; 0.729 ± 0.018 and 0.776 ± 0.023 p < 0.000001, respectively). VVRx values were significantly higher in men (0.775 ± 0.046 and 0.747 ± 0.091, p = 0.019, respectively), while ХVRx values were significantly higher in women (0.665 ± 0.018 and 0.728 ± 0.024, p < 0.0000001, respectively).

Conclusions: SARS-CoV-2 (COVID-19) of moderate severity is accompanied by a significant deterioration in eye tracking performance proving functional and structural impairments (p < 0.05). VVRx was significantly higher in men, and HVRx was substantially greater in women reflecting gender-specific differences.

Keywords: COVID-19; Eye tracking; Vergence.