Chimney endovascular aneurysm repair-induced mesenteric ischemia: a report of an extremely rare complication

J Vasc Surg Cases Innov Tech. 2023 Jul 4;9(3):101259. doi: 10.1016/j.jvscit.2023.101259. eCollection 2023 Sep.

Abstract

The chimney endovascular aneurysm repair (Ch-EVAR) technique has progressively increased in popularity in the treatment of complex aortic aneurysms. However, the long-term results of this technique still must be assessed, especially in comparison to custom-made solutions. The patency of chimney grafts has always been one of the important issues with the Ch-EVAR technique. However, interactions between nonstented aortic side branches and chimney stent grafts have rarely been discussed. In the present case report, we describe a rare case of mesenteric ischemia due to superior mesenteric artery ostium coverage by the misalignment of a renal stent graft in a Ch-EVAR.

Keywords: Case report; Ch-EVAR; Chimney; EVAR; Mesenteric ischemia.

Publication types

  • Case Reports