Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait-A Preliminary Study

Sensors (Basel). 2023 Jul 28;23(15):6744. doi: 10.3390/s23156744.

Abstract

In-shoe models are required to extend the clinical application of current multisegment kinetic models of the bare foot to study the effect of foot orthoses. Work to date has only addressed marker placement for reliable kinematic analyses. The purpose of this study is to address the difficulties of recording contact forces with available sensors. Ten participants walked 5 times wearing two different types of footwear by stepping on a pressure platform (ground contact forces) while wearing in-shoe pressure sensors (foot sole contact forces). Pressure data were segmented by considering contact cells' anteroposterior location, and were used to compute 3D moments at foot joints. The mean values and 95% confidence intervals were plotted for each device per shoe condition. The peak values and times of forces and moments were computed per participant and trial under each condition, and were compared using mixed-effect tests. Test-retest reliability was analyzed by means of intraclass correlation coefficients. The curve profiles from both devices were similar, with higher joint moments for the instrumented insoles at the metatarsophalangeal joint (~26%), which were lower at the ankle (~8%) and midtarsal (~15%) joints, although the differences were nonsignificant. Not considering frictional forces resulted in ~20% lower peaks at the ankle moments compared to previous studies, which employed force plates. The device affected both shoe conditions in the same way, which suggests the interchangeability of measuring joint moments with one or the other device. This hypothesis was reinforced by the intraclass correlation coefficients, which were higher for the peak values, although only moderate-to-good. In short, both considered alternatives have drawbacks. Only the instrumented in-soles provided direct information about foot contact forces, but it was incomplete (evidenced by the difference in ankle moments between devices). However, recording ground reaction forces offers the advantage of enabling the consideration of contact friction forces (using force plates in series, or combining a pressure platform and a force plate to estimate friction forces and torque), which are less invasive than instrumented insoles (which may affect subjects' gait).

Keywords: force plate; in-shoe model; instrumented insoles; multisegment kinetic foot model; pressure platform.

MeSH terms

  • Biomechanical Phenomena
  • Foot Joints
  • Foot*
  • Gait
  • Humans
  • Reproducibility of Results
  • Shoes*