Long locking plate combined with locking attachment plate in patients with periprosthetic femoral fracture around ipsilateral stem after total knee arthroplasty

BMC Musculoskelet Disord. 2023 Jul 20;24(1):594. doi: 10.1186/s12891-023-06726-x.

Abstract

Background: The purpose of this study was to introduce the surgical technique using long locking plate and locking attachment plate (LAP) in patient with periprosthetic femoral fracture around ipsilateral stem after total knee arthroplasty (TKA). Moreover, we sought to investigate the outcomes of this fixation technique and to propose a new subtype in the existing classification of periprosthetic femoral fractures.

Methods: From January 2013 to January 2022, thirty-four consecutive periprosthetic femoral fractures around ipsilateral stem following TKA with minimum 1-year follow-up were enrolled in this study. Most cases were fixed with long-locking plate and LAP using the MIPO technique. For subgroup analysis, we classified patients with stemmed hip implant (group H) and stemmed knee implant (group K). Bone union, American Knee Society Score (AKSS) scale, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, the Western Ontario and McMaster Universities Osteoarthritis Index for pain and function, and range of motion were investigated.

Results: The number of group H and K were 24 patients (70.6%) and 10 patients (29.4%), respectively. The mean age at operation was 71.5 years (range, 65‒85 years), and the mean follow-up period was 27.5 months (range, 12‒72 months). Bone union was confirmed radiographically in all patients, and the mean union time was 4.9 months (range, 3.5‒6 months). There were no significant differences in radiographic and clinical outcomes between the groups.

Conclusions: Long-locking plate combined with LAP showed favorable radiographic and clinical outcomes in patients with periprosthetic femoral fracture around ipsilateral stem after TKA.

Level of evidence: Level IV, Retrospective Case Series.

Keywords: Locking Attachment Plate; Long Locking Plate; Periprosthetic femoral fracture; Stemmed Implantation; Total knee arthroplasty.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Arthroplasty, Replacement, Hip*
  • Arthroplasty, Replacement, Knee* / adverse effects
  • Arthroplasty, Replacement, Knee* / methods
  • Bone Plates
  • Femoral Fractures* / diagnostic imaging
  • Femoral Fractures* / etiology
  • Femoral Fractures* / surgery
  • Fracture Fixation, Internal / adverse effects
  • Fracture Fixation, Internal / methods
  • Fracture Healing
  • Humans
  • Osteoarthritis* / surgery
  • Periprosthetic Fractures* / diagnostic imaging
  • Periprosthetic Fractures* / etiology
  • Periprosthetic Fractures* / surgery
  • Retrospective Studies
  • Treatment Outcome