New-onset atrial high-rate episodes between his bundle pacing and conventional right ventricular septum pacing in patients with atrioventricular conduction disturbance

J Interv Card Electrophysiol. 2024 Apr;67(3):471-477. doi: 10.1007/s10840-023-01605-w. Epub 2023 Jul 3.

Abstract

Background: The effect of His bundle pacing (HBP) on the incidence of new-onset atrial fibrillation (AF) after pacemaker implantation (PMI) for atrioventricular conduction disturbance (AVCD) remains unknown. We compared the incidence of new-onset atrial high-rate episode (AHRE) in conventional right ventricular (RV) septum pacing (RVSP) and His bundle pacing (HBP) after PMI for AVCD.

Methods: One hundred and four consecutive patients who underwent dual chamber PMI for AVCD in our hospital were screened. Thirty-five patients with mitral or aortic valve disease, history of open-heart surgery, prior AF, subclinical AF, cumulative ventricular pacing percentage < 90%, and RV lead revision were excluded, and 69 patients were effectively enrolled in this study. The primary endpoint was new-onset AHRE within the follow-up period. New-onset AHRE was defined as an atrial high-rate episode that occurred 3 months after PMI and lasted for > 6 min at an atrial heart rate > 190 bpm. RV leads were placed in the His bundle region and RV septum region in 22 and 47 patients, respectively. The mean follow-up period was 539 ± 218 days. The follow-up period was 2 years after PMI or until the new-onset AHRE occurred.

Results: The incidence of new-onset AHRE was lower in the HBP group than in the RVSP group (11% vs. 43%, p = 0.01). Multivariate analysis in the Cox regression hazard model showed that HBP had a significantly lower risk of new-onset AHRE compared with RVSP (HR = 0.21; 95% confidence interval 0.04-0.78, p = 0.02).

Conclusion: The incidence of new-onset AHRE was significantly less in HBP compared to RVSP during the 2-year follow-up period after pacemaker implantation in AVCD patients with RV pacing dependence.

Keywords: Atrioventricular conduction disturbance; Electrocardiography; His bundle pacing; New-onset atrial high-rate episode; Pacemaker; Right ventricular pacing dependence.

MeSH terms

  • Atrial Fibrillation* / epidemiology
  • Atrial Fibrillation* / etiology
  • Atrial Fibrillation* / therapy
  • Bundle of His
  • Cardiac Pacing, Artificial / adverse effects
  • Electrocardiography
  • Humans
  • Pacemaker, Artificial* / adverse effects
  • Treatment Outcome
  • Ventricular Septum*