Consequences of Using Post- or Prebronchodilator Reference Values in Interpreting Spirometry

Am J Respir Crit Care Med. 2023 Aug 15;208(4):461-471. doi: 10.1164/rccm.202212-2341OC.

Abstract

Rationale: Postbronchodilator spirometry is used for the diagnosis of chronic obstructive pulmonary disease. However, prebronchodilator reference values are used for spirometry interpretation. Objectives: To compare the resulting prevalence rates of abnormal spirometry and study the consequences of using pre- or postbronchodilator reference values generated within SCAPIS (Swedish CArdioPulmonary bioImage Study) when interpreting postbronchodilator spirometry in a general population. Methods: SCAPIS reference values for postbronchodilator and prebronchodilator spirometry were based on 10,156 and 1,498 never-smoking, healthy participants, respectively. We studied the associations of abnormal spirometry, defined by using pre- or postbronchodilator reference values, with respiratory burden in the SCAPIS general population (28,851 individuals). Measurements and Main Results: Bronchodilation resulted in higher predicted medians and lower limits of normal (LLNs) for FEV1/FVC ratios. The prevalence of postbronchodilator FEV1/FVC ratio lower than the prebronchodilator LLN was 4.8%, and that of postbronchodilator FEV1/FVC lower than the postbronchodilator LLN was 9.9%, for the general population. An additional 5.1% were identified as having an abnormal postbronchodilator FEV1/FVC ratio, and this group had more respiratory symptoms, emphysema (13.5% vs. 4.1%; P < 0.001), and self-reported physician-diagnosed chronic obstructive pulmonary disease (2.8% vs. 0.5%, P < 0.001) than subjects with a postbronchodilator FEV1/FVC ratio greater than the LLN for both pre- and postbronchodilation. Conclusions: Pre- and postbronchodilator spirometry reference values differ with regard to FEV1/FVC ratio. Use of postbronchodilator reference values doubled the population prevalence of airflow obstruction; this was related to a higher respiratory burden. Using postbronchodilator reference values when interpreting postbronchodilator spirometry might enable the identification of individuals with mild disease and be clinically relevant.

Keywords: post-bronchodilator; pre-bronchodilator; reference values; respiratory burden; spirometry.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Forced Expiratory Volume
  • Humans
  • Pulmonary Disease, Chronic Obstructive* / diagnosis
  • Pulmonary Disease, Chronic Obstructive* / epidemiology
  • Reference Values
  • Spirometry
  • Vital Capacity