Transcatheter Tricuspid Valve Replacement With a Dedicated Device in a Patient With 2 Endocardial Leads

JACC Case Rep. 2023 Apr 28:15:101848. doi: 10.1016/j.jaccas.2023.101848. eCollection 2023 Jun 7.

Abstract

A 79-year-old woman with a history of dilated cardiomyopathy who required a permanent peacemaker, recently upgraded to implantable cardioverter-defibrillator cardiac resynchronization therapy, was admitted for right heart failure. On echocardiography, torrential tricuspid regurgitation was noted, with 2 leads across the valve. After multidisciplinary evaluation, a dedicated transcatheter valve replacement was successfully implanted. (Level of Difficulty: Intermediate.).

Keywords: endocardial leads; transcatheter tricuspid valve replacement; tricuspid regurgitation.

Publication types

  • Case Reports