Electrocatalytic barium-oxide decorated MWCNT amperometric sensor for the quantification of anesthetic drug Procaine

Colloids Surf B Biointerfaces. 2023 Jul:227:113363. doi: 10.1016/j.colsurfb.2023.113363. Epub 2023 May 22.

Abstract

Procaine hydrochloride (P.HCl) is one of the earliest and most well-established local anesthetic drugs used in medicine. Though it is employed frequently for effective clinical nerve blocks during surgeries, its immoderate administration has often shown reports of systemic toxicity. To prevent such repercussions, developing a sensor for the drug is crucial to enable real-time monitoring of the drug and assist in quality control procedures during its industrial preparations. Thus, in this work, we have fabricated a simple yet highly selective and sensitive amperometric sensor for P.HCl detection based on a Barium-oxide multi-wall carbon nanotube-modified carbon paste electrode (BaO-MWCNT/CPE). Herein, we have adopted a novel approach devoid of sophisticated procedures and pretreatments for rapidly determining P.HCl. Furthermore, experimental conditions, including supporting electrolytes, pH, and scan rate, were optimized to achieve a well-defined P.HCl anodic peak current at 631 mV, which is lower than the previously reported peak potentials, indicating an advantage of reduced overpotential. Besides, a striking 66-fold rise in current responsiveness to P.HCl was achieved upon modification with BaO-MWCNT. Such an intense signal enhancement upon electrode modification compared to bare CPE was due to the strong electrocatalytic feature of BaO-MWCNT, which was verified using surface morphology studies with scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Additionally, the charge transfer kinetics analyzed via electrochemical impedance spectroscopy (EIS) justified the enhancement of electrocatalytic activity upon electrode modification. The developed sensor exhibited a remarkable analytical performance over a wide linear dynamic range of 2.0-100.0 µM with a detection limit of 0.14 µM. Moreover, a significant merit of this sensor is its excellent selectivity towards P.HCl even in the presence of various common interferants. Finally, the versatility of the sensor was further validated by implementing it for the trace analysis of urine and blood serum real samples.

Keywords: Amperometry; Carbon electrode; Electroanalysis; Electrocatalytic activity; Procaine.

MeSH terms

  • Anesthetics*
  • Barium
  • Electrochemical Techniques
  • Electrodes
  • Oxides
  • Pharmaceutical Preparations
  • Procaine*

Substances

  • Procaine
  • Barium
  • Pharmaceutical Preparations
  • Anesthetics
  • barium oxide
  • Oxides