Successful Endovascular Rescue Using the Brockenbrough Needle Following Inadvertent Stent-Graft Deployment in the False Lumen

J Tehran Heart Cent. 2022 Jul;17(3):147-151. doi: 10.18502/jthc.v17i3.10848.

Abstract

Inadvertent deployment of stent grafts into the false lumen during thoracic endovascular aortic repair (TEVAR) is rare and is associated with catastrophic consequences. We present a case of accidental stent-graft deployment from the true lumen into the false lumen during TEVAR, resulting in hemodynamic collapse and visceral malperfusion. We successfully performed a bailout using the Brockenbrough needle to create new access from the true lumen to the false lumen and implanted another overlapping stent graft.

Keywords: Brockenbrough needle; Endovascular rescue; False lumen implantation; Thoracic endovascular aortic repair (TEVAR).

Publication types

  • Case Reports