Design of a Double-Photoelectrode Sensing System with a Metal-Organic Framework-Based Antenna-like Strategy for Highly Sensitive Detection of PD-L1

Anal Chem. 2023 Jun 6;95(22):8720-8727. doi: 10.1021/acs.analchem.3c01516. Epub 2023 May 24.

Abstract

Currently, the construction of heterojunctions as a method to enhance photoelectrochemical (PEC) activity has shown prospective applications in the analytical field. Restricted by carrier separation at the interface, developing a heterojunction sensing platform with high sensitivity remains challenging. Here, a double-photoelectrode PEC sensing platform was fabricated based on an antenna-like strategy by integrating MIL-68(In)-NH2, a p-type metal-organic framework (MOF) photocatalyst, as a photocathode with the type-II heterojunction of CdSe/MgIn2S4 as a photoanode synchronously. According to the ligand-to-metal charge transition (LMCT), the photo-generated carriers of MIL-68(In)-NH2 transferred from the organic ligand to the metal cluster, which provides an efficient antenna-like transfer path for the charge at the heterojunction interface. In addition, the sufficient Fermi energy difference between the double photoelectrode provides the continuous internal driving force required for rapid carrier separation at the anode detection interface, significantly improving the photoelectric conversion efficiency. Hence, compared with the traditional heterojunction single electrode, the photocurrent response of the double-photoelectrode PEC sensing platform developed using the antenna-like strategy is 2.5 times stronger. Based on this strategy, we constructed a PEC biosensor for the detection of programed death-ligand 1 (PD-L1). The elaborated PD-L1 biosensor exhibited sensitive and precise detection capability with a detection range of 1 × 10-5 to 1 × 103 ng/mL and a lower detection limit of 3.26 × 10-6 ng/mL and demonstrated the feasibility of serum sample detection, providing a novel and viable approach for the unmet clinical need of PD-L1 quantification. More importantly, the charge separation mechanism at the heterojunction interface proposed in this study provides new creative inspiration for designing sensors with high-sensitivity PEC performance.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • B7-H1 Antigen
  • Biosensing Techniques* / methods
  • Electrochemical Techniques
  • Gold
  • Ligands
  • Limit of Detection
  • Metal-Organic Frameworks*

Substances

  • Metal-Organic Frameworks
  • B7-H1 Antigen
  • Ligands
  • Gold