Validation of a predictive model for speech discrimination after cochlear impIant provision

HNO. 2023 Aug;71(Suppl 1):53-59. doi: 10.1007/s00106-023-01285-y. Epub 2023 May 4.

Abstract

Background: If sufficient speech discrimination is no longer achieved with conventional hearing systems, an audiological indication for a cochlear implant (CI) is given. However, there are no established target criteria for CI aftercare with regard to the level of speech comprehension to be achieved. The aim of this study is to validate an existing predictive model for speech comprehension after CI provision. This is applied to different patient groups.

Materials and methods: The prospective study included 124 postlingually deaf adults. The model is based on preoperative maximum monosyllabic recognition score, aided monosyllabic recognition score at 65 dBSPL, and age the time of implantation. The model was investigated with regard to prediction accuracy for monosyllabic recognition with CI after 6 months.

Results: Mean speech discrimination improved from 10% with hearing aid to 65% with CI after 6 months, with a statistically significant improvement in 93% of cases. Deterioration of aided unilateral speech discrimination was not observed. The mean prediction error was 11.5 percentage points in the cases with preoperative scores better than zero and 23.2 percentage points in all other cases.

Conclusion: Cochlear implantation should also be considered in patients with moderately severe to severe hearing loss and insufficient speech discrimination with hearing aids. The model based on preoperatively measured data for predicting speech discrimination with CI can be used in preoperative consultation and in the context of postoperative quality assurance.

Keywords: Hearing aids; Hearing loss; Hearing tests; Speech audiometry; Speech discrimination tests.

MeSH terms

  • Adult
  • Cochlear Implantation*
  • Cochlear Implants*
  • Hearing Aids*
  • Humans
  • Prospective Studies
  • Speech
  • Speech Perception*