Association of acute improvement in left ventricular longitudinal function after transcatheter aortic valve implantation with outcomes for severe aortic stenosis and preserved ejection fraction

J Cardiol. 2023 Oct;82(4):234-239. doi: 10.1016/j.jjcc.2023.04.008. Epub 2023 Apr 19.

Abstract

Background: Global longitudinal strain (GLS) is reportedly a sensitive marker for early subtle abnormalities in left ventricular (LV) performance of asymptomatic patients with severe aortic stenosis (AS) and preserved LV ejection fraction (LVEF). For symptomatic patients with severe AS and preserved LVEF, however, the association of immediate improvement in GLS after transcatheter aortic valve implantation (TAVI) with long-term outcomes remains uncertain.

Methods: This study concerned 151 symptomatic patients with severe AS and preserved LVEF who had undergone TAVI. Echocardiography was performed before TAVI and 7 (7-9) days after TAVI. GLS was determined by means of a two-dimensional speckle-tracking strain using current guidelines. The primary endpoint was defined as a composite endpoint comprising cardiovascular death or re-hospitalization for HF after TAVI over a median follow-up period of 27.7 (11.9-51.4) months.

Results: Mean LVEF and GLS were 65 ± 7 % and 12.8 ± 3.4 %, respectively. The Kaplan-Meier curve indicated that patients with acute improvement in GLS after TAVI experienced fewer cardiovascular events than those without such improvement (log-rank P = 0.02). Multivariate analysis showed that non-acute improvement in GLS after TAVI was independently associated with worse outcomes as well as deterioration of the mean transaortic pressure gradient.

Conclusion: Assessment of GLS immediately after TAVI is a valuable additional parameter for better management of symptomatic patients with severe AS and preserved LVEF who are scheduled for TAVI.

Keywords: Aortic stenosis; Echocardiography; Global longitudinal strain; Transcatheter aortic valve implantation.

MeSH terms

  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / surgery
  • Humans
  • Retrospective Studies
  • Stroke Volume
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome
  • Ventricular Dysfunction, Left* / diagnostic imaging
  • Ventricular Dysfunction, Left* / etiology
  • Ventricular Function, Left