Estimation of skeletal muscle mass in 4-year-old children using the D3-creatine dilution method

Pediatr Res. 2023 Sep;94(3):1195-1202. doi: 10.1038/s41390-023-02587-1. Epub 2023 Apr 10.

Abstract

Background: Given limited experience in applying the creatine-(methyl-D3) (D3Cr) dilution method to measure skeletal muscle mass (SMM) in young children, the feasibility of deployment in a fielding setting and performance of the method was assessed in a cohort of 4-year-old children in Dhaka, Bangladesh.

Methods: Following D3Cr oral dose (10 mg) administration, single fasting urine samples were collected at 2-4 days (n = 100). Twenty-four-hour post-dose collections and serial spot urine samples on days 2, 3 and 4 were obtained in a subset of participants (n = 10). Urinary creatine, creatinine, D3Cr and D3-creatinine enrichment were analyzed by liquid chromatography-tandem mass spectrometry. Appendicular lean mass (ALM) was measured by dual-energy x-ray absorptiometry and grip strength was measured by a hand-held dynamometer.

Results: SMM was measured successfully in 91% of participants, and there were no adverse events. Mean ± SD SMM was greater than ALM (4.5 ± 0.4 and 3.2 ± 0.6 kg, respectively). Precision of SMM was low (intraclass correlation = 0.20; 95% CI: 0.02, 0.75; n = 10). Grip strength was not associated with SMM in multivariable analysis (0.004 kg per 100 g of SMM; 95% CI: -0.031, 0.038; n = 91).

Conclusions: The D3Cr dilution method was feasible in a community setting. However, high within-child variability in SMM estimates suggests the need for further optimization of this approach.

Impact: The D3-creatine (D3Cr) stable isotope dilution method was considered a feasible method for the estimation of skeletal muscle mass (SMM) in young children in a community setting and was well accepted among participants. SMM was weakly associated with both dual-energy x-ray absorptiometry-derived values of appendicular lean mass and grip strength. High within-child variability in estimated values of SMM suggests that further optimization of the D3Cr stable isotope dilution method is required prior to implementation in community research settings.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Absorptiometry, Photon / methods
  • Bangladesh
  • Body Composition / physiology
  • Child, Preschool
  • Creatine* / metabolism
  • Creatinine / metabolism
  • Humans
  • Isotopes / metabolism
  • Muscle, Skeletal* / metabolism

Substances

  • Creatine
  • Creatinine
  • Isotopes