Evaluating the influence of sleep quality and quantity on glycemic control in adults with type 1 diabetes

Front Endocrinol (Lausanne). 2023 Feb 22:14:998881. doi: 10.3389/fendo.2023.998881. eCollection 2023.

Abstract

Background: Sleep quality disturbances are frequent in adults with type 1 diabetes. However, the possible influence of sleep problems on glycemic variability has yet to be studied in depth. This study aims to assess the influence of sleep quality on glycemic control.

Materials and methods: An observational study of 25 adults with type 1 diabetes, with simultaneous recording, for 14 days, of continuous glucose monitoring (Abbott FreeStyle Libre system) and a sleep study by wrist actigraphy (Fitbit Ionic device). The study analyzes, using artificial intelligence techniques, the relationship between the quality and structure of sleep with time in normo-, hypo-, and hyperglycemia ranges and with glycemic variability. The patients were also studied as a group, comparing patients with good and poor sleep quality.

Results: A total of 243 days/nights were analyzed, of which 77% (n = 189) were categorized as poor quality and 33% (n = 54) as good quality. Linear regression methods were used to find a correlation (r =0.8) between the variability of sleep efficiency and the variability of mean blood glucose. With clustering techniques, patients were grouped according to their sleep structure (characterizing this structure by the number of transitions between the different sleep phases). These clusters showed a relationship between time in range and sleep structure.

Conclusions: This study suggests that poor sleep quality is associated with lower time in range and greater glycemic variability, so improving sleep quality in patients with type 1 diabetes could improve their glycemic control.

Keywords: clustering techniques; glucose behavior prediction; glycemic control; sleep structure; statistical analysis.

Publication types

  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Artificial Intelligence
  • Blood Glucose
  • Blood Glucose Self-Monitoring
  • Diabetes Mellitus, Type 1* / complications
  • Glycemic Control
  • Humans
  • Sleep Quality
  • Sleep Wake Disorders*

Substances

  • Blood Glucose

Grants and funding

This work has been supported by: Fundación Eugenio Rodriguez Pascual 2019 grant -Desarrollo de sistemas adaptativos y bioin-spirados para el control glucémico con infusores subcutáneos continuos de insulina y monitores continuos de glucosa (Development of adaptive and bioinspired systems for glycemic control with continuous subcutaneous insulin infusors and continuous glucose monitors). The Spanish Ministerio de Innovación Ciencia y Universidad -grants PID2021-125549OB-I00, PDC2022-133429-I00 and RTI2018-095180-B-I00. Madrid Regional Government -FEDER grants B2017/BMD3773 (GenObIA-CM) and Y2018/NMT-4668 (Micro-Stress-MAP-CM).