Posterior Protrusion Measures (PPM) as an Innovative Index in Classifying Plain Lateral Radiograph Images of Pertrochanteric Fracture Using the Revised AO Foundation/Orthopaedic Trauma Association (AO/OTA) Classification

Cureus. 2022 Dec 24;14(12):e32898. doi: 10.7759/cureus.32898. eCollection 2022 Dec.

Abstract

Introduction The absence of a precise fracture classification system that classifies pertrochanteric fractures into either stable or unstable contributes to a burden on healthcare and has several major implications. We propose an innovative graphical index, which we refer to as posterior protrusion measures (PPM), using plain lateral view radiograph images for the revised AO Foundation (Arbeitsgemeinschaft für Osteosynthesesfragen)/Orthopedic Trauma Association (AO/OTA) classification system. This study aims to: (i) introduce the use of PPM for classifying fractures into stable or unstable under the revised AO/OTA classification system and set the threshold numeric value, (ii) elucidate the reproducibility of inter and intra-observer agreement, and investigate the consistency of fracture classification using PPM versus computed tomography (CT) scan images. Materials and methods Out of 146 patients identified from the database, a total of 126 patients were enrolled in the study. Pertrochanteric fractures were classified as either stable or unstable. Three surgeons were assigned for PPM determination. Regarding the demographical data, the chi-square test was used to assess the significance of each parameter on a categorical scale between the two groups. The independent sample t-test or the Mann-Whitney U test was used to compare the two independent groups. Interclass correlation coefficient (ICC) values for continuous variables and kappa values (κ) for categorical variables were calculated to assess inter-observer and intra-observer agreement. Receiver-operating characteristic (ROC) analysis was used to determine optimal cut-off points of PPM to predict consistency between separate fracture classification groups, one using PPM values with a threshold derived from plain radiograph images, and the other using CT scan images. Results Among a total of 126 pertrochanteric fractures, the A1 (stable) group consisted of 39 patients (10 males, 29 females), whereas the A2 (unstable) group consisted of 87 patients (14 males, 73 females) (not significant, NS). Intraclass correlation coefficient (ICC) values of PPM for the inter-observer agreement were 0.796 (0.723-0.852), 0.664 (0.554-0.751), and 0.702 (0.601-0.781) at first examination and 0.729 (0.635-0.801) at the second. The intra-observer agreement was 0.869 (0.819-0.906) and 0.603 (0.480-0.703). We examined for consistency of fracture classification group of PPM values with a threshold of 0.4 (A1<0.4, A2=0.4 or more) and CT-based group. For the first examination, there was mostly "moderate" agreement in fracture classification (stable or unstable) between plain radiograph and CT scan images, κ (95%CI): 0.427 (0.266-0.588), 0.493 (0.335-0.651), and 0.359 (0.176-0.544), and for the second, 0.418 (0.251-0.585), and 0.451 (0.284-0.620), respectively. Conclusion We propose a supplementary tool, namely PPM that allows for possible alternative classification of pertrochanteric fractures into A1 (stable) and A2 (unstable) using plain radiograph images under the revised AO/OTA classification system. In this study, a PPM threshold value of 0.4 demonstrated a moderate inter- and intra-observer agreement. It is noteworthy to mention that there was a satisfactory consistency of fracture classification using PPM derived from plain radiograph images when compared to classification using CT scan images. In addition, the PPM method provides a numerical score.

Keywords: ao/ota classification; lateral view; pertrochanteric fracture; plain radiograph; posterior protrusion measures.