Development of a Duplex LAMP Assay with Probe-Based Readout for Simultaneous Real-Time Detection of Schistosoma mansoni and Strongyloides spp. -A Laboratory Approach to Point-Of-Care

Int J Mol Sci. 2023 Jan 3;24(1):893. doi: 10.3390/ijms24010893.

Abstract

Loop-mediated isothermal amplification (LAMP) is the most popular technology for point-of-care testing applications due its rapid, sensitive and specific detection with simple instrumentation compared to PCR-based methods. Many systems for reading the results of LAMP amplifications exist, including real-time fluorescence detection using fluorophore-labelled probes attached to oligonucleotide sequences complementary to the target nucleic acid. This methodology allows the simultaneous detection of multiple targets (multiplexing) in one LAMP assay. A method for multiplexing LAMP is the amplification by release of quenching (DARQ) technique by using a 5'-quencher modified LAMP primer annealed to 3'-fluorophore-labelled acting as detection oligonucleotide. The main application of multiplex LAMP is the rapid and accurate diagnosis of infectious diseases, allowing differentiation of co-infecting pathogens in a single reaction. Schistosomiasis, caused among other species by Schistosoma mansoni and strongyloidiasis, caused by Strongyloides stercoralis, are the most common helminth-parasite infections worldwide with overlapping distribution areas and high possibility of coinfections in the human population. It would be of great interest to develop a duplex LAMP to detect both pathogens in the same reaction. In this study, we investigate the use of our two previously developed and well-stablished LAMP assays for S. mansoni and Strongyloides spp. DNA detection in a new duplex real-time eight-primer system based on a modified DARQ probe method that can be performed in a portable isothermal fluorimeter with minimal laboratory resources. We also applied a strategy to stabilize the duplexed DARQ-LAMP mixtures at room temperature for use as ready-to-use formats facilitating analysis in field settings as point-of-care diagnostics for schistosomiasis and strongyloidiasis.

Keywords: DARQ-LAMP; LAMP; Schistosoma mansoni; Strongyloides spp.; diagnostic; duplex LAMP; multiplex LAMP; point-of-care.

MeSH terms

  • Animals
  • DNA, Helminth / genetics
  • Fluorescent Dyes
  • Humans
  • Nucleic Acid Amplification Techniques / methods
  • Oligonucleotides
  • Point-of-Care Systems
  • Schistosoma mansoni / genetics
  • Schistosomiasis*
  • Sensitivity and Specificity
  • Strongyloides stercoralis* / genetics
  • Strongyloidiasis*

Substances

  • DNA, Helminth
  • Oligonucleotides
  • Fluorescent Dyes

Supplementary concepts

  • LAMP assay