Microwave ablation using two simultaneous antennas for the treatment of liver malignant lesions: a 3 year single-Centre experience

Int J Hyperthermia. 2023;40(1):2163309. doi: 10.1080/02656736.2022.2163309.

Abstract

Background: sequential or simultaneous applications of multiple antennas have been proposed to create larger ablation zone; however, there is a lack of data in patients affected by liver tumors, with potentially different results from animal liver models. The purpose of this study was to evaluate efficacy and safety of liver percutaneous microwave ablation using simultaneous activation of two antennas to treat lesions bigger than 2,5 cm; particularly the focus was assessing whether the ratio of ablation zone volume in millimeters to applied energy in kilojoules [R(AZ:E)] differs between hepatocellular carcinoma in a cirrhotic liver and liver metastasis and if it is correlated to complications incidence or recurrence of disease.

Methods: Fifty-five liver microwave ablation performed with two simultaneous antennas from March 2017 to June 2021 were retrospectively reviewed; 9 procedures were excluded due to the association with Chemoembolization. Size, shape, volume of lesions and ablation zones were recorded. Technical success was defined as complete devascularization of the treated area at the post-procedural CT. R(AZ:E) was determined dividing the ablation zone volume in mm3 by the amount of energy in kilojoules applied in each procedure and complications were reported.

Results: Technical success was achieved in all the procedures. Mean R(AZ:E) was 0,75 ± 0,58. T-student test for patients with HCC and patients with metastasis about R(AZ:E) was significant (p = 0.03). The incidence of bilomas was lower for HCC (p = 0.022). One-month follow-up showed Complete Response (CR) in 44/46 (95,6%) patients; Three-six months follow-up demonstrated: CR in 43/46 (93.5%) cases and 12 months follow-up highlighted CR in 40/45 (88,9%) cases.

Conclusions: These results provide preliminary evidence of efficacy and safety of simultaneous liver MWA using two antennas, highlighting the importance of procedural indications.

Keywords: Thermal ablation; [R(AZ:E)]; hepatocellular carcinoma; liver metastases; microwave; multi-probe.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Carcinoma, Hepatocellular* / pathology
  • Catheter Ablation* / methods
  • Liver Neoplasms* / diagnostic imaging
  • Liver Neoplasms* / pathology
  • Liver Neoplasms* / surgery
  • Microwaves / therapeutic use
  • Retrospective Studies
  • Treatment Outcome