Five-Strand Hamstring Grafts are Biomechanically Comparable to Four-Strand Grafts and Offer Greater Diameter for Anterior Cruciate Ligament Reconstruction

Arthrosc Sports Med Rehabil. 2022 Aug 13;4(5):e1731-e1738. doi: 10.1016/j.asmr.2022.06.020. eCollection 2022 Oct.

Abstract

Purpose: The purpose of this study was to compare the biomechanics of 4-strand and 5-strand hamstring constructs for anterior cruciate ligament grafts.

Methods: Thirty-six human cadaveric hamstring grafts were tested in 3 different conditions: (1) graft femoral fixation complex, (2) graft femoral and tibial fixation (GFTF) complex using a human model, and (3) GFTF complex using a porcine model. Grafts were tested on a tensile testing machine. Four-stranded grafts served as the control group, and 5-stranded grafts served as the experimental group. Cyclic elongation, ultimate load to failure, stiffness, and diameter of the grafts were analyzed.

Results: Average 4-strand graft diameter was 7.96 mm compared to 9.32 mm for the 5-strand graft (P = .00017). Average stiffness of grafts ≥8 mm was 105.04 N/mm compared to 85.05 N/mm for grafts <8 mm (P = .04988). There was a positive correlation between graft diameter and stiffness (13.4 N/mm per every 1 mm increase in diameter, r 2 value of 13.1%, and F-significance of 0.02778). There were no significant differences in terms of ultimate load to failure, cyclic elongation, or stiffness between the experimental groups.

Conclusion: Five-strand hamstring grafts offer greater diameter and are biomechanically comparable to 4-strand equivalents at time 0. Grafts >8 mm offer significantly greater stiffness compared to grafts sized <8 mm. There is a weak positive correlation between graft diameter and stiffness.

Clinical relevance: A potential drawback to hamstring grafts is their variability in size. Five-strand hamstring grafts provide increased diameter in comparison to 4-strand equivalents and might be used when quadrupled graft diameter is <8 mm.