Universal newborn eye screening: a systematic review of the literature and review of international guidelines

J Glob Health. 2022 Oct 21:12:12003. doi: 10.7189/jogh.12.12003.

Abstract

Background: This systematic review assessed the effectiveness of universal screening for newborn eye abnormalities compared with no screening in improving infant vision and health outcomes.

Methods: We searched CENTRAL (Cochrane Library), MEDLINE, Embase, Global Health, Global Index Medicus, clinical trials databases, and bibliographies of relevant articles. We included randomized and observational studies of all newborns, regardless of illness or risk factors, that compared universal screening for any eye abnormality by eight weeks of age with no universal screening. Two authors independently selected studies, extracted data, and evaluated the risk of bias. We used GRADE to assess the certainty of evidence. We also reviewed available recommendations on newborn eye screening.

Results: Fourteen studies were identified but only three compared universal red reflex screening with no screening. Findings suggest that universal red reflex testing in maternity wards (MWs) may increase the number of newborns with congenital cataracts referred for eye care from MWs or well-baby clinics (WBCs) in the first year of life (risk ratio (RR) = 9.83, 95% confidence interval (CI) = 1.36-71.20; low certainty evidence). However, the effect of screening in WBC is uncertain (RR = 6.62, 95% CI = 0.87-50.09). The effect of MW or WBC screening on referral from any health care facility (MWs, WBCs, paediatrician clinic, other) in the first year is uncertain (MW screening: RR = 1.22, 95% CI = 0.63-2.39; WBC screening: RR = 0.97, 95% CI = 0.46-2.05). However, referral or surgery by 6 weeks of age may be higher with universal MW screening (early referral: RR = 4.61, 95% CI = 1.12-19.01; early surgery: RR = 8.23, 95% CI = 1.13-59.80; low certainty evidence). The effect of WBC screening on early referral and surgery is uncertain (early referral: RR = 1.98, 95% CI = 0.43-9.19; early surgery: RR = 3.97, 95% CI = 0.50-31.33; very low certainty evidence). Universal red reflex testing may increase clinical conjunctivitis (OR = 1.22, 95% CI = 1.01-1.47; low certainty evidence) but the effect on confirmed bacterial conjunctivitis is uncertain (OR = 1.20, 95% CI = 0.76-1.90; very low-certainty evidence). Nine guidelines recommended universal newborn eye screening using red reflex testing.

Conclusions: Evidence supports the role of red reflex testing shortly after birth to increase early identification, referral, and surgery for congenital cataracts.

Publication types

  • Systematic Review

MeSH terms

  • Cataract*
  • Female
  • Humans
  • Infant
  • Infant, Newborn
  • Pregnancy