Navigation Template Design and the Anatomic Measurement for Anterograde Transpubic Screws

Orthop Surg. 2022 Dec;14(12):3408-3416. doi: 10.1111/os.13510. Epub 2022 Oct 17.

Abstract

Objective: For pelvic ring fractures, screw fixation became a popular technique for its good biomechanical performance. The safe insertion of anterograde the transpubic screw is important for patients with anterior pelvic ring fractures. This paper is to research the anatomical parameters of the anterograde transpubic screw corridor and evaluate the safety of anterograde transpubic screw placement assisted by the assembled navigation template.

Methods: Fifty subjects with normal pelvic, 25 men and 25 women, age from 20 to 60 were enrolled, and their ilium were 3D reconstructed. The ilium was divided into zone I, zone II and zone III. Zone I and zone III was defined as medial and lateral to the obturator foramen, respectively. Zone II is located between zones I and III. The corridor A is formed by zone I and zone II and corridor B is formed by zone I, zone II and zone III. The diameter and length of the inner circle, the distance from the center of the inner circle to the posterior superior and to the inferior iliac spine of corridor A and corridor B were measured, respectively. Nine patients with pelvic fractures underwent anterograde transpubic screw and transverse sacroiliac screw placement assisted by the assembled navigation template and were retrospectively analyzed. Operation time, blood loss, incision length and fluoroscopy times were recorded. Grading score and Matta score were evaluated after surgery.

Results: In the 50 subjects, the diameter of corridor A was 11.16 ± 2.13 mm, and that of corridor B was 8.54 ± 1.52 mm. The length of corridor A was 86.39 ± 9.35 mm, and that of corridor B was 117.05 ± 5.91 mm. The surface distance from the screw entry point to the posterior superior iliac spine in corridor A was 109.31 ± 11.06 mm, and that in corridor B was 127.86 ± 8.23 mm. The surface distance from the screw entry point to the posterior inferior iliac spine in corridor A was 91.16 ± 10.34 mm, and that in corridor B was 106.92 ± 7.91 mm. A total of 18 sacroiliac transverse screws and 11 anterograde transpubic screws were inserted assisted by assembled navigation templates for nine patients. The average operation time was 108.75 ± 25.71 min, the blood loss was 141.11 ± 50.21 ml, the incision length was 14 ± 4.62 cm, and the intraoperative fluoroscopy was 17.89 ± 4.01 times.

Conclusion: Transpubic screw corridor can be obtained by 3D reconstruction. For the majority of patients, the anterograde pubic ramus corridor accommodated a 6.5 mm diameter screw. It is safe to use anterograde transpubic screw placement assisted by an assembled navigation template.

Keywords: 3D printing; Anatomy; Anterograde transpubic screw; Minimally invasive; Pelvic fracture.

MeSH terms

  • Bone Screws*
  • Female
  • Fractures, Bone* / surgery
  • Humans
  • Pelvis*
  • Retrospective Studies