Oxygen Challenge Imaging Reveals Differences in Metabolic Activity Between Kurtosis Lesion and Diffusion/Kurtosis Lesion Mismatch in a Rodent Model of Acute Stroke

J Comput Assist Tomogr. 2022 Sep-Oct;46(5):792-799. doi: 10.1097/RCT.0000000000001333.

Abstract

Objective: Accurate identification of potentially salvageable tissues is critical for improving acute stroke treatment. A previous study showed that the kurtosis lesion exhibited insignificant response after prompt reperfusion treatment, while the diffusion/kurtosis lesion mismatch could recover after reperfusion. We hypothesized that these 2 regions are in different metabolic states.

Materials and methods: Transient oxygen challenge (OC) is a procedure that uses oxygen as a metabolic bio-tracer and has been performed to explore metabolic activity in tissues. We combined OC with multiparameter magnetic resonance imaging (including diffusion kurtosis imaging and T2* mapping sequences) to study metabolic activity in the ischemic brain of Sprague Dawley rats.

Results: Oxygen challenge image analysis revealed changes in T2* values, most significantly in the mean diffusivity (MD)/mean kurtosis (MK) lesion mismatch (22.3 ± 1.6%) and least significantly in the MK lesions (6.6 ± 0.6%). The MD images acquired within 138 ± 9 minutes after ischemia showed a larger ischemic lesion (45.5 ± 3.0% of the total area) than the MK images (33.2 ± 4.2% of the total area). The change rate of the MK value (53.0 ± 4.4%) was higher than that of the MD value (37.5 ± 3.2%).

Conclusions: The present study shows that MK lesion and MD/MK lesion mismatch exhibited different metabolic activity states. The MK lesion presented metabolic-related values close to the ischemic core, while at least part of the MD/MK mismatch area was comparable with ischemic penumbra metabolic activity. These findings are important to support image-guided individualized stroke therapies.