The Effects of High Energy Capsulotomy on Aqueous Cytokine Profiles and Pupil Size During Femtosecond Laser-Assisted Cataract Surgery

J Refract Surg. 2022 Sep;38(9):587-594. doi: 10.3928/1081597X-20220808-01. Epub 2022 Sep 1.

Abstract

Purpose: To assess whether aqueous cytokine profiles and pupil size are altered when high capsulotomy energy is used in eyes undergoing femtosecond laser-assisted cataract surgery (FLACS), and if preoperative use of a topical non-steroidal anti-inflammatory drug (NSAID) has an effect on this.

Methods: This prospective study recruited 83 eyes (63 patients) that were allocated to four treatment groups: conventional phacoemulsification (n = 20 eyes); FLACS with 90% capsulotomy energy without NSAID pretreatment (n = 20 eyes); FLACS with 90% capsulotomy energy with NSAID pre-treatment (n = 21 eyes); and FLACS with 150% capsulotomy energy with NSAID pretreatment (n = 22 eyes). Aqueous humor was collected before and after phacoemulsification to assess cytokine profiles. Pupil size was measured before and after laser capsulotomy.

Results: FLACS increased aqueous concentrations of pros-taglandin E2 (PGE2), interferon γ (IFN-γ), and interleukin 6 (IL-6) compared to conventional phacoemulsification. However, when increasing capsulotomy energy from 90% to 150% (with topical NSAID pretreatment), there was no significant increase in aqueous concentrations of PGE2 (37.7 ± 21.7 vs 33.6 ± 27.6 pg/mL, P = .99), IFN-γ (3.6 ± 1.1 vs 3.6 ± 0.8 pg/mL, P = .99), or IL-6 (7.1 ± 2.9 vs 6.3 ± 2.4 pg/mL, P = .99). For 90% and 150% capsulotomy energy, there was significant miosis following laser capsulotomy. Increased PGE2 concentration was significantly correlated with a reduction in pupil area (r = -0.58, P < .001) and pupil diameter (r = -0.57, P < .001). However, when a topical NSAID was given preoperatively, there was no difference in the degree of miosis between the 90% and 150% capsulotomy energy groups.

Conclusions: Pretreatment with a topical NSAID prevented a rise in PGE2, IFN-γ, and IL-6 levels and excessive miosis when a higher capsulotomy energy was used. When a topical NSAID is used preoperatively, it is safe to use higher capsulotomy energy settings (with a low pulse energy femtosecond laser system) to achieve a satisfactory capsulotomy. [J Refract Surg. 2022;38(9):587-594.].

MeSH terms

  • Anti-Inflammatory Agents, Non-Steroidal / therapeutic use
  • Cataract* / etiology
  • Humans
  • Interleukin-6 / pharmacology
  • Laser Therapy* / adverse effects
  • Lasers
  • Miosis
  • Prospective Studies
  • Prostaglandins E / pharmacology
  • Pupil

Substances

  • Anti-Inflammatory Agents, Non-Steroidal
  • Interleukin-6
  • Prostaglandins E