Electrocardiographic Changes Associated with Early Repolarization Pattern in Healthy Young Males

Medicina (Kaunas). 2022 Aug 4;58(8):1048. doi: 10.3390/medicina58081048.

Abstract

Background and Objectives: Early repolarization pattern (ERP) has recently been shown to be related with an increased risk of ventricular arrhythmias in susceptible individuals. Materials and Methods: We studied the ERP-associated ECG changes, with potential clinical relevance, in 220 young (age 22.1 ± 1.6 years), healthy, male subjects using 12-lead ECG recordings. A total of 38 subjects (17.3%) fulfilled the diagnostic criteria for ERP, and a total of 90 ECG characteristics were compared between the groups of subjects with and without ERP. Results: None of the ECGs were pathological, and 22 ECG parameters differed significantly (p < 0.05) between the subjects with and without ERP. Among them, the P wave-related parameters (e.g., average P wave duration: 101.5 ± 9.2 ms vs. 106.8 ± 9.9 ms, p = 0.004) and the presence of fragmented QRS complexes (67.6% vs. 92.1%, p = 0.002) revealed a potential propensity for atrial and ventricular arrhythmogenesis. The time-domain parameters of repolarization, those not corrected for QRS duration, showed shorter values (e.g., Tpeak-Tend interval: 70.9 ± 8.1 ms vs. 67.8 ± 8.0 ms, p = 0.036), reflecting the accelerated repolarization. Conclusions: Certain ECG characteristics seem to be more associated with ERP. The clinical significance of this finding at the individual level needs further prospective investigations.

Keywords: P wave; Tpeak-Tend interval; early repolarization pattern; fragmented QRS.

MeSH terms

  • Adult
  • Arrhythmias, Cardiac* / diagnosis
  • Electrocardiography*
  • Humans
  • Male
  • Young Adult