Pre-operative Aortic Neck Characteristics and Post-operative Sealing Zone as Predictors of Type 1a Endoleak and Migration After Endovascular Aneurysm Repair: A Systematic Review and Meta-Analysis

Eur J Vasc Endovasc Surg. 2022 Nov;64(5):475-488. doi: 10.1016/j.ejvs.2022.08.017. Epub 2022 Aug 19.

Abstract

Objective: Establishing the predictive value of neck characteristics and real achieved sealing zone is essential to foster risk stratified procedure selection and imaging surveillance. This systematic review provides an overview of pre-operative aortic neck characteristics and post-operative real achieved sealing zone and their respective risk of type 1a endoleak and migration after endovascular aneurysm repair (EVAR).

Methods: In agreement with PRISMA guidelines, MEDLINE, Embase, and Cochrane CENTRAL were searched. Data on neck characteristics, sealing zone, and EVAR outcome were extracted. Meta-analyses were performed to investigate the effect of neck diameter, angulation, and shape on type 1a endoleak (total, early ≤ 90 days, and late > 90 days) and migration in patients who underwent EVAR. A qualitative summary was also provided.

Results: Thirty-three studies were included. Patients with a larger neck diameter had an increased risk of total type 1a endoleak (nine studies: OR 3.32, 95% CI 2.38 - 4.63), early type 1a endoleak (six studies: OR 2.64, 95% CI 1.27 - 5.48), late type 1a endoleak (six studies: OR 3.26, 95% CI 2.12 - 5.03), and migration (seven studies: OR 2.88, 95% CI 1.32 - 6.26). An angulated neck increased the risk of total type 1a endoleak (seven studies: OR 4.27, 95% CI 1.55 - 11.78) and late type 1a endoleak (seven studies: OR 5.56, 95% CI 2.19 - 14.13). Neck shape was not associated with type 1a endoleak. Neck length and real achieved sealing zone on post-EVAR computed tomography were identified as risk factors for type 1a endoleak and migration through qualitative summary.

Conclusion: There seems to be some consistent evidence that aortic neck diameter, angulation, and length are associated with the development of type 1a endoleak or migration. Real achieved sealing zone might be an important addition during follow up. However, a small number of studies, with serious limitations, could be included, and there was considerable variability in reporting patients and outcomes. A proposal for standardisation of aortic and EVAR data in future studies is provided.

Keywords: Abdominal aortic aneurysm; Aortic neck; EVAR; Endovascular aneurysm repair; Neck characteristics; Sealing zone.

Publication types

  • Meta-Analysis
  • Systematic Review
  • Review

MeSH terms

  • Aortic Aneurysm, Abdominal* / complications
  • Aortic Aneurysm, Abdominal* / diagnostic imaging
  • Aortic Aneurysm, Abdominal* / surgery
  • Blood Vessel Prosthesis / adverse effects
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Endoleak / diagnostic imaging
  • Endoleak / etiology
  • Endoleak / surgery
  • Endovascular Procedures* / adverse effects
  • Humans
  • Retrospective Studies
  • Risk Factors
  • Time Factors
  • Treatment Outcome