Comparison of Colonoscopy, Fecal Immunochemical Test, and Risk-Adapted Approach in a Colorectal Cancer Screening Trial (TARGET-C)

Clin Gastroenterol Hepatol. 2023 Mar;21(3):808-818. doi: 10.1016/j.cgh.2022.08.003. Epub 2022 Aug 11.

Abstract

Background & aims: The screening yield and related cost of a risk-adapted screening approach compared with established screening strategies in population-based colorectal cancer (CRC) screening are not clear.

Methods: We randomly allocated 19,373 participants into 1 of the 3 screening arms in a 1:2:2 ratio: (1) one-time colonoscopy (n = 3883); (2) annual fecal immunochemical test (FIT) (n = 7793); (3) annual risk-adapted screening (n = 7697), in which, based on the risk-stratification score, high-risk participants were referred for colonoscopy and low-risk ones were referred for FIT. Three consecutive screening rounds were conducted for both the FIT and the risk-adapted screening arms. Follow-up to trace the health outcome for all the participants was conducted over the 3-year study period. The detection rate of advanced colorectal neoplasia (CRC and advanced precancerous lesions) was the main outcome. The trial was registered in the Chinese Clinical Trial Registry (number: ChiCTR1800015506).

Results: In the colonoscopy, FIT, and risk-adapted screening arms over 3 screening rounds, the participation rates were 42.4%, 99.3%, and 89.2%, respectively; the detection rates for advanced neoplasm (intention-to-treat analysis) were 2.76%, 2.17%, and 2.35%, respectively, with an odds ratio (OR)colonoscopy vs FIT of 1.27 (95% confidence interval [CI]: 0.99-1.63; P = .056), an ORcolonoscopy vsrisk-adapted screening of 1.17 (95% CI, 0.91-1.49; P = .218), and an ORrisk-adapted screeningvs FIT of 1.09 (95% CI, 0.88-1.35; P = .438); the numbers of colonoscopies needed to detect 1 advanced neoplasm were 15.4, 7.8, and 10.2, respectively; the costs for detecting 1 advanced neoplasm from a government perspective using package payment format were 6928 Chinese Yuan (CNY) ($1004), 5821 CNY ($844), and 6694 CNY ($970), respectively.

Conclusions: The risk-adapted approach is a feasible and cost-favorable strategy for population-based CRC screening and therefore could complement the well-established one-time colonoscopy and annual repeated FIT screening strategies. (Chinese Clinical Trial Registry; ChiCTR1800015506).

Keywords: Colonoscopy; Colorectal Cancer Screening; Fecal Immunochemical Test; Personalized Screening; Risk Stratification.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Colonoscopy
  • Colorectal Neoplasms* / diagnosis
  • Early Detection of Cancer*
  • Feces
  • Humans
  • Mass Screening
  • Occult Blood
  • Risk Factors