3D high resolution clonogenic survival measurement of xrs-5 cells in low-dose region of carbon ion plans

Int J Radiat Biol. 2023;99(3):488-498. doi: 10.1080/09553002.2022.2110318. Epub 2022 Aug 15.

Abstract

Purpose: In this study, we performed biological verification measurements of cell survival of a 12C ion irradiation plan employing a high-resolution 3D culture setup. This allowed, in particular, to access the cell inactivation in the low-dose regions close to the target area.

Materials and methods: We established the protocol for a 3D culture setup where xrs-5 cells were grown inside a layered matrigel structure in 384-well plates. Their radiosensitivity to conventional and 12C ion radiation was evaluated by irradiating them either with 250 kV X-rays at GSI or with monoenergetic 12C beams of 110 MeV/u at MIT, and compared with those of monolayers. A treatment plan for a rectangular target was prepared using the GSI research treatment planning system TRiP98. xrs-5 cells were seeded in the matrigel-based setup and irradiated in dose fall-off regions using active scanning 12C ion beams. In addition, film dosimetry utilizing radiochromic EBT3 film has been performed to assess the field homogeneity downstream of 384-well V-bottom plates with or without additional agarose coating of the well plate bottom.

Results: Dose response curves following X-ray and 12C ion irradiation had linear shape and showed a significant decrease in survival fraction at even moderate doses. Survival measurements in the low-dose regions of the plan for the extended target showed good agreement to the predicted survival fraction. The irradiated film profiles yielded a flat dose distribution without apparent artifacts or inhomogeneities for well plates both with and without agarose coating, confirming the suitability of the experimental setup.

Conclusions: We conclude that the V-bottom 384-well plates in combination with the radiation-sensitive xrs-5 cell line constitute a suitable radiobiological verification tool which can be used especially for low doses. Furthermore, the measured survival of xrs-5 cells show a good agreement with the expected survival in the low-dose out-of-field regions, both laterally and downstream of the target.

Keywords: 3D cell culture in ECM; biological treatment plan verification; carbon ion beam therapy; xrs-5 cells.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Carbon*
  • Ions
  • Radiobiology*
  • Radiometry
  • Sepharose
  • X-Rays

Substances

  • Sepharose
  • Ions
  • Carbon