A new metal-free benzorhodol-based photoluminophore selective for carbon monoxide detection applicable in both in vitro and in vivo bioimaging

Anal Methods. 2022 Aug 25;14(33):3196-3202. doi: 10.1039/d2ay00835a.

Abstract

A new benzorhodol-based non-fluorescent organic frame (DEB-CO) detects carbon monoxide (CO) selectively through a spirolactam ring-opening mechanism. Herein, the selective off-on fluorogenic behavior of this probe towards CO has been achieved without any assistance of precious and hazardous metals (e.g. Pd2+) as additional substrates. Moreover, the red-emissive probe motivated us to apply in situ tracing in mice and living cells. The selective off-on fluorogenic behavior of this probe towards CO originating from CORM-3 in vitro and in vivo with a limit of detection as low as 64.29 nM (for CORM-3) has been observed. Additionally, this probe is capable of sensing toxic carbon monoxide gas. This probe has also been utilized to detect intracellular CO in MCF7 cells (in vitro) and to spot the distribution of CO in mice (in vivo) by acquiring bioimages with the help of confocal microscopy, which indicates that DEB-CO is a smart competent probe for this purpose.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Carbon Monoxide*
  • Fluorescent Dyes*
  • Humans
  • MCF-7 Cells
  • Metals
  • Mice
  • Microscopy, Confocal

Substances

  • Fluorescent Dyes
  • Metals
  • Carbon Monoxide