Risk Factors for Incomplete Aortic Remodeling With Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair for Complicated Aortic Dissection: Results of a Multicenter Study

J Endovasc Ther. 2024 Feb;31(1):69-79. doi: 10.1177/15266028221111984. Epub 2022 Jul 25.

Abstract

Purpose: The STABILISE technique has extended the treatment of aortic dissection to the thoracoabdominal aorta to achieve complete aortic remodeling. The aim of this multicenter study was to analyze the short- and midterm anatomical results of the STABILISE technique.

Materials and methods: We retrospectively analyzed patients treated with the STABILISE technique for complicated aortic dissection at 3 French academic centers. The aortic diameter at different levels was measured preoperatively, postoperatively, and at 1 year.

Results: Between 2018 and 2020, 58 patients, including 47 men (average patient age: 60±11 years), were treated for type B aortic dissection in 34 cases and residual aortic dissection after type A repair in 24 cases. Three (5.2%) patients died postoperatively. Complete aortic remodeling (false lumen thrombosis and complete reapposition of the intimal flap) was achieved in 45/55 patients (81.8%), and false lumen thrombosis in the thoracic aorta was achieved in 52/55 patients (94.5%). At 1 year, with a computed tomographic (CT) scan available for 98.2% (54/55) of patients, we observed a significant decrease in the maximal thoracic aortic diameter and a significant increase in the aortic diameter at the bare-stent level compared with the preoperative CT scan. Severe aortic angulation (p=0.024) was a risk factor for incomplete aortic remodeling and significantly increased the aortic diameter (p=0.032). Chronic aortic dissection was associated with an increased risk of incomplete aortic remodeling (p=0.002).

Conclusions: STABILISE for complicated aortic dissection results in false lumen thrombosis, complete reapposition of the intimal flap, and a decrease in the maximum aortic diameter in most cases. Incomplete reapposition of the intimal flap, which is more frequent in cases of chronic aortic dissection and severe aortic angulation, is a risk factor for a significant increase in the aortic diameter at the bare-stent level, and this risk justifies close follow-up and better patient selection.

Clinical impact: STABILISE technique for complicated aortic dissection results in false lumen thrombosis, complete aortic remodeling and a decrease in the maximum aortic diameter in most cases. At the bare-stent level, incomplete reapposition of the intimal flap, more frequent in chronic aortic dissection and severe aortic angulation, is a risk factor for an increased aortic diameter. This finding justifies close follow-up and better patient selection; thus, the STABILISE technique should be used with care in chronic aortic dissection and severe aortic angulation.

Keywords: STABILISE technique; TEVAR; anatomical results; aneurysm evolution; aortic dissection; risk factors.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Aorta
  • Aortic Dissection* / diagnostic imaging
  • Aortic Dissection* / surgery
  • Humans
  • Male
  • Middle Aged
  • Retrospective Studies
  • Risk Factors
  • Stents
  • Thrombosis*
  • Treatment Outcome