Does stress shielding after radial head arthroplasty affect functional outcomes?

Eur J Orthop Surg Traumatol. 2023 Jul;33(5):1591-1598. doi: 10.1007/s00590-022-03315-x. Epub 2022 Jun 28.

Abstract

Background: Various complications related to the prosthesis, such as implant loosening and stress shielding phenomenon, could develop after prosthetic replacement of the radial head. Stress shielding is known to occur around rigidly fixed implants. The purpose of this study was to evaluate the clinical influence and causative factors of the stress shielding phenomenon after radial head arthroplasty (RHA).

Methods: Clinical records and radiographs of 56 patients with unreconstructable radial head fractures who received radial head replacement between 2009 and 2019 were reviewed. Exclusion criteria were infection, loosening, and follow-up of less than 24 months. After exclusion, 35 patients were enrolled. Patients were divided into two groups: an anatomical press-fit group (Anatomical Radial Head System; Acumed, Hillsboro, OR, USA) and a round bipolar cemented group (RHS; Tornier, Montbonnot Saint-Martin, France). Stress shielding around the prosthesis was assessed in the serial radiological examination. Clinical results were assessed using Mayo elbow performance score (MEPS), Quick Disabilities of the Arm, Shoulder, and Hand (q-DASH) score, range of motion (flexion-extension arc and pronation-supination arc), and visual analog scale score (VAS). Correlations between stress shielding phenomenon and demographic data and functional results were analyzed.

Results: At an average follow-up of 43.06 (± 14.6) months, 14 (40%) out of 35 fixed stems demonstrated stress shielding. Our results showed that the rate of stress shielding was significantly higher in cases with a bilateral ligament injury and in the anatomical press-fit group (p = 0.028 and p = 0.0091, respectively). However, stress shielding around prostheses did not affect the clinical results (p > 0.05).

Conclusion: The stress shielding phenomenon around radial head prosthesis may vary according to prosthetic design and severity of ligament injuries. Stress shielding does not affect the mid-term outcomes in the treatment of acute fractures of the radial head.

Level of evidence iii: Retrospective Cohort Comparison; Treatment Study.

Keywords: Radial head arthroplasty; Radial head fractures; Stress shielding.

MeSH terms

  • Arthroplasty
  • Elbow Joint*
  • Elbow Prosthesis*
  • Humans
  • Radius / diagnostic imaging
  • Radius / surgery
  • Radius Fractures* / surgery
  • Range of Motion, Articular
  • Retrospective Studies
  • Treatment Outcome