Determination of isoscoparin in mouse blood using UPLC-MS/MS and its pharmacokinetics

Biomed Chromatogr. 2022 Sep;36(9):e5419. doi: 10.1002/bmc.5419. Epub 2022 Jun 6.

Abstract

This study developed a UPLC-MS/MS method to detect isoscoparin in mouse blood, determined the pharmacokinetics of isoscoparin in mice after intravenous (5 mg/kg) and intragastric (20 mg/kg) administration, and calculated the absolute bioavailability. A HSS T3 column was used for separation, and the column temperature was set at 40°C. The mobile phases were acetonitrile and 0.1% formic acid, and the gradient elution procedure was used. The blood sample was treated with protein precipitant with acetonitrile-methanol (9:1, v/v). Multiple reaction monitoring mode was used for quantitative analysis in electrospray positive-ion mode. It showed a good linear relationship in the range of 1-4000 ng/mL (r > 0.998); the intra-day and inter-day precision was <12%, and the accuracy was 86-112%. The recovery was >68%, and the matrix effect was 86-90%. The half-life of isoscoparin was relatively short in mice, and the bioavailability was 2.6%. The developed UPLC-MS/MS method was rapid, sensitive, and suitable for the pharmacokinetics of isoscoparin in mice.

Keywords: UPLC-MS/MS; bioavailability; isoscoparin; pharmacokinetics.