Micropulse Transscleral Cyclophotocoagulation for Glaucoma after Penetrating Keratoplasty

Diagnostics (Basel). 2022 May 5;12(5):1143. doi: 10.3390/diagnostics12051143.

Abstract

The main objective of the article was to assess the surgical outcome of micropulse transscleral cyclophotocoagulation in patients presenting with glaucoma after penetrating keratoplasty. We conducted a retrospective study that included 26 eyes of 26 patients who presented with glaucoma after penetrating keratoplasty, and who were treated using micropulse transscleral cyclophotocoagulation between January 2017 and December 2020. The surgeries were performed using the Iridex Cyclo G6 MicroPulse P3 Probe. The intraocular pressure, mean number of antiglaucoma medications, visual acuity, corneal status, and postoperative complications were analyzed. The minimum follow-up period was 12 months. The success rate after 12 months was 76.9%. The baseline median intraocular pressure was 29 mm Hg and decreased to 18 mm Hg after 12 months. The median number of antiglaucoma medications was also reduced from three preoperatively to one after one year. In seven cases (29.92%), the visual acuity decreased and, in four cases (15.38%), the corneal graft was not transparent. We concluded that micropulse transscleral cyclophotocoagulation is an effective and safe method for the treatment of glaucoma after penetrating keratoplasty.

Keywords: glaucoma; micropulse; postkeratoplasty; transscleral cyclophotocoagulation.

Grants and funding

This research received no external funding.