Robot-Assisted Versus Conventional Freehand Fluoroscopy-Guided Percutaneous Screw Fixation in Femoral Neck Fractures: A Systematic Review and Meta-analysis

Cureus. 2022 Apr 18;14(4):e24258. doi: 10.7759/cureus.24258. eCollection 2022 Apr.

Abstract

Robotic-assisted navigation for percutaneous femoral neck fracture fixation is a new technology that has shown enhanced intraoperative and postoperative outcomes compared to the conventional freehand fluoroscopy-guided technique. The authors aim to compare robot-assisted femoral neck fracture fixation to conventional freehand fluoroscopy-guided repair. Electronic databases were searched, identifying all observational studies comparing outcomes of both groups. Using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, a systematic review and meta-analysis were conducted. The primary outcomes included operative duration (minutes), intraoperative bleeding (mL), fluoroscopy exposure, and frequency of intraoperative drilling. The secondary outcomes included Harris scores, healing rate and time, screw accuracy, and postoperative complications. Seven observational studies were identified, enrolling 506 patients. There was a significant difference between the robot-assisted and conventional groups in terms of intraoperative blood loss (mean difference (MD) = -18.83, p ≤ 0.05), fluoroscopy exposure (MD = -1.81, p ≤ 0.05), and intraoperative drilling frequency (MD = -7.35, p < 0.05). There was no significant difference in operative duration between the groups (MD = -0.21, p = 0.66). Most secondary outcomes were improved in the robot-assisted group. Overall, robot-assisted fixation was superior in terms of safety and efficacy.

Keywords: femoral neck; fixation; fracture; percutaneous; robot assisted.

Publication types

  • Review