Temperature Measurement of Hot Airflow Using Ultra-Fine Thermo-Sensitive Fluorescent Wires

Sensors (Basel). 2022 Apr 21;22(9):3175. doi: 10.3390/s22093175.

Abstract

In this paper, we propose a temperature measurement method that uses ultrafine fluorescent wires to reduce the wire diameter to a much lesser extent than a thermocouple. This is possible because its structure is simple and any material can be used for the wire. Hence, ultrafine wires with a Reynolds number of less than 1.0 can be selected. Ultra-fine wires less than 50 µm in diameter were set in the test volume. The wire surfaces were coated with fluorescent paint. The test volume was illuminated using an ultraviolet light-emitting diode. The paint emits very tiny, orange-colored fluorescent light with an intensity that changes with the temperature of the atmosphere. The experimental results showed that the heating/cooling layers were well visualized and the temperature field was well analyzed.

Keywords: LIF; airflow; fluorescent paint; temperature measurement.