Anatomical feasibility of the current endovascular solutions for Juxtarenal aortic abdominal aneurysm repair

Vascular. 2023 Oct;31(5):833-840. doi: 10.1177/17085381221097304. Epub 2022 May 5.

Abstract

Purpose: Endovascular repair of juxta-renal aneurysms (JAAAs) can be achieved by fenestrated endografts (FEVAR), parallel-grafts (CHEVAR) and standard abdominal endografts + endoanchors (ESAR). Aim of this study was to evaluate the incidence of their anatomical feasibility in JAAAs.

Materials and methods: All patients submitted to JAAAs treatment from 2006 to 2019 were retrospectively analyzed, irrelevant of the procedure performed. Juxta-renal aneurysm was defined according with the current ESVS clinical practice guidelines. Preoperative computed tomography angiographies were analyzed to evaluate the anatomical feasibility of: FEVAR (Cook Zenith-platform; CE-marked or custom-made device), CHEVAR (Medtronic Endurant + Atrium Advanta - CE marked combination) and ESAR (Medtronic Endurant + Helifix - CE marked combination) according with the manufactures' instruction for use. The anatomical feasibility of these three endovascular solutions was assessed according with the proximal neck, target visceral vessels (TVVS) and iliac access characteristics.

Results: Ninety-nine cases were considered. There were no cases of frank aortic rupture and in all patients at least one arterial access from above was available. Fenestrated endograft, CHEVAR, and ESAR were anatomically feasible in 93 (94%), 37 (37%), and 27 (27%) cases, respectively (p <. 001). Fenestrated endograft requires design with <3, three and >3 fenestrations in 29 (31%), 33 (36%), and 31 (33%) cases, respectively. Parallel graft technique have required 1 or 2 parallel graft configurations in 12 (12%) and 25 (25%) cases, respectively. Among the 14 cases with aneurysm diameter >70 mm, the anatomical feasibility of FEVAR, CHEVAR, and ESAR was 13(93%), 4(29%), and 4 (29%) cases, respectively (p < .001).

Conclusion: Fenestrated endograft is more frequently applicable than CHEVAR and ESAR as endovascular treatment of JAAAs. Since this difference is valid also in aneurysms with diameter >70 mm, the issue of a rapid availability is of paramount importance. The 6% of cases have not any endovascular solution and requires open surgery.

MeSH terms

  • Aortic Aneurysm, Abdominal* / diagnostic imaging
  • Aortic Aneurysm, Abdominal* / etiology
  • Aortic Aneurysm, Abdominal* / surgery
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Endovascular Procedures* / adverse effects
  • Feasibility Studies
  • Humans
  • Prosthesis Design
  • Retrospective Studies
  • Treatment Outcome