Intensity standardization of MRI prior to radiomic feature extraction for artificial intelligence research in glioma-a systematic review

Eur Radiol. 2022 Oct;32(10):7014-7025. doi: 10.1007/s00330-022-08807-2. Epub 2022 Apr 29.

Abstract

Objectives: Radiomics is a promising avenue in non-invasive characterisation of diffuse glioma. Clinical translation is hampered by lack of reproducibility across centres and difficulty in standardising image intensity in MRI datasets. The study aim was to perform a systematic review of different methods of MRI intensity standardisation prior to radiomic feature extraction.

Methods: MEDLINE, EMBASE, and SCOPUS were searched for articles meeting the following eligibility criteria: MRI radiomic studies where one method of intensity normalisation was compared with another or no normalisation, and original research concerning patients diagnosed with diffuse gliomas. Using PRISMA criteria, data were extracted from short-listed studies including number of patients, MRI sequences, validation status, radiomics software, method of segmentation, and intensity standardisation. QUADAS-2 was used for quality appraisal.

Results: After duplicate removal, 741 results were returned from database and reference searches and, from these, 12 papers were eligible. Due to a lack of common pre-processing and different analyses, a narrative synthesis was sought. Three different intensity standardisation techniques have been studied: histogram matching (5/12), limiting or rescaling signal intensity (8/12), and deep learning (1/12)-only two papers compared different methods. From these studies, histogram matching produced the more reliable features compared to other methods of altering MRI signal intensity.

Conclusion: Multiple methods of intensity standardisation have been described in the literature without clear consensus. Further research that directly compares different methods of intensity standardisation on glioma MRI datasets is required.

Key points: • Intensity standardisation is a key pre-processing step in the development of robust radiomic signatures to evaluate diffuse glioma. • A minority of studies compared the impact of two or more methods. • Further research is required to directly compare multiple methods of MRI intensity standardisation on glioma datasets.

Keywords: Glioma; Magnetic resonance imaging; Reproducibility of results.

Publication types

  • Systematic Review

MeSH terms

  • Artificial Intelligence*
  • Glioma* / diagnostic imaging
  • Humans
  • Magnetic Resonance Imaging / methods
  • Reference Standards
  • Reproducibility of Results