Long-term outcomes following drug-eluting balloons vs. thin-strut drug-eluting stents for treatment of recurrent restenosis in drug-eluting stents

Kardiol Pol. 2022;80(7-8):765-773. doi: 10.33963/KP.a2022.0106. Epub 2022 Apr 21.

Abstract

Background: There is limited data on the optimal revascularization strategy in patients with recurrent in-stent restenosis (R-ISR).

Aims: To compare the long-term outcomes of patients treated with either a thin-strut drug-eluting stent (thin-DES) or a drug-eluting balloon (DEB) for R-ISR in a drug-eluting stent (DES).

Methods: A multicenter DEB-DRAGON registry was used to retrospectively identify patients with R-ISR who received either a thin-DES or a DEB. Propensity score matching was applied to adjust for baseline differences. The primary outcome was target lesion revascularization (TLR).

Results: Out of 311 patients (mean age, 67 years; 63% male) with R-ISR, 86 (27.7%) were treated with a thin-DES and 225 (72.3%) with a DEB. Median follow-up was 2.6 years. TLR occurred in 18 (20.9%) patients who received thin-DES and 61 (27.1%) patients treated with DEB (hazard ratio [HR], 0.57; 95% confidence interval [CI], 0.33-0.98; log-rank P = 0.04). The difference remained significant in a propensity score-matched cohort of 57 patients treated with thin-DES and 57 patients treated with a DEB (17.5 vs. 33.3%, respectively; HR, 0.38; 95% CI, 0.17-0.86; P = 0.01). The risks of device-oriented adverse cardiac events and all-cause mortality were similar after thin-DES or DEB in both unadjusted and propensity score-matched cohorts. In a multivariable Cox proportional hazard model, the treatment with a thin-DES was an independent predictor of a TLR-free survival (HR, 0.33; 95% CI 0.13-0.84; P = 0.02).

Conclusions: In patients with R-ISR implantation of a thin-DES is associated with a lower risk of repeated revascularization compared with angioplasty with a DEB.

Keywords: drug-eluting balloon; drug-eluting stent; percutaneous coronary intervention; recurrent in-stent restenosis; revascularization.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Angioplasty, Balloon, Coronary* / adverse effects
  • Cardiac Catheters
  • Coated Materials, Biocompatible
  • Coronary Restenosis* / etiology
  • Coronary Restenosis* / surgery
  • Drug-Eluting Stents* / adverse effects
  • Female
  • Humans
  • Male
  • Percutaneous Coronary Intervention* / adverse effects
  • Retrospective Studies
  • Risk Factors
  • Treatment Outcome

Substances

  • Coated Materials, Biocompatible