Background: Limited data exist on the circadian blood pressure (BP) and heart rate (HR) variations that occur in heart failure (HF) patients on left ventricular assist device (LVAD) support.
Methods: We prospectively recorded clinic and 24-hour ambulatory BP and HR data in patients on HeartMate II LVAD support. Results were compared to HF patients with ejection fraction ≤30% and controls with no history of cardiovascular disease. Physiologic nocturnal BP and HR dipping was defined as a ≥10% decline compared to daytime values.
Result: Twenty-nine LVAD patients (age 59 ± 15 years, 76% male, 38% ischemic etiology), 25 HF patients (age 64 ± 13 years, 84% male, 32% ischemic etiology) and 26 controls (age 56 ± 9 years, 62% male) were studied. Normal nocturnal BP dipping was less frequent in LVAD patients (10%) than in HF patients (28%) and controls (62%) and reversed BP dipping (BP increase at night) was more common in LVAD patients (24%), compared to HF (16%) and controls (8%), (p < 0.001, for all comparisons). Physiologic HR reduction was less frequent in LVAD patients (14%), compared to HF (16%) and controls (59%) (p < 0.001, for all comparisons). Among LVAD patients, 36% exhibited sustained hypertension over the 24-hours and 25% had white-coat hypertension.
Conclusions: Treatment of advanced HF with an LVAD does not restore physiologic circadian variability of BP and HR; additionally, BP was not adequately controlled in more than a third of LVAD patients, and a quarter of them exhibited white-coat hypertension. Future studies are warranted to confirm these findings and investigate prognostic and management implications in this population.
Keywords: 24-hour blood pressure; ABPM; LVAD; circadian variability; night dipping; ventricle assist device.
Copyright © 2022 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.