A Deep Learning Approach for Detecting Otitis Media From Wideband Tympanometry Measurements

IEEE J Biomed Health Inform. 2022 Jul;26(7):2974-2982. doi: 10.1109/JBHI.2022.3159263. Epub 2022 Jul 1.

Abstract

Objective: In this study, wepropose an automatic diagnostic algorithm for detecting otitis media based on wideband tympanometry measurements.

Methods: We develop a convolutional neural network for classification of otitis media based on the analysis of the wideband tympanogram. Saliency maps are computed to gain insight into the decision process of the convolutional neural network. Finally, we attempt to distinguish between otitis media with effusion and acute otitis media, a clinical subclassification important for the choice of treatment.

Results: The approach shows high performance on the overall otitis media detection with an accuracy of 92.6%. However, the approach is not able to distinguish between specific types of otitis media.

Conclusion: Out approach can detect otitis media with high accuracy and the wideband tympanogram holds more diagnostic information than the commonly used techniques wideband absorbance measurements and simple tympanograms.

Significance: This study shows how advanced deep learning methods enable automatic diagnosis of otitis media based on wideband tympanometry measurements, which could become a valuable diagnostic tool.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acoustic Impedance Tests / methods
  • Deep Learning*
  • Humans
  • Otitis Media with Effusion* / diagnosis
  • Otitis Media* / diagnosis