Choline Proline Ionic Liquid-Functionalized Fe3O4@SiO2 Nanoparticle Magnetic Solid Phase Extraction Coupled with High-Performance Liquid Chromatography for Analysis of Allura Red in Lipstick Sample

J Cosmet Sci. 2021 Jul-Aug;72(4):347-361.

Abstract

A separation/analysis of allura red based on magnetic solid-phase extraction-high-performance liquid chromatography was developed. The extractant was prepared by functionalizing choline proline ionic liquid on Fe3O4@SiO2(Fe3O4@SiO2@[Ch][Pro]). Infl uences of experimental variables including extraction condition (material amount, pH, time, temperature, ionic strength, and sample volume) and elution conditions (eluent selection, amount, time) were evaluated. Under the optimal conditions, good linear calibration curves were obtained in the range of 0.02-5.0 μg/mL, and limits of detection was 9.0 ng/mL. The proposed method was successfully applied for the determination of allura red in lipstick sample.

MeSH terms

  • Azo Compounds
  • Choline
  • Chromatography, High Pressure Liquid / methods
  • Ionic Liquids* / chemistry
  • Limit of Detection
  • Magnetic Phenomena
  • Nanoparticles*
  • Proline
  • Silicon Dioxide / chemistry
  • Solid Phase Extraction / methods

Substances

  • Azo Compounds
  • Ionic Liquids
  • Allura Red AC Dye
  • Silicon Dioxide
  • Proline
  • Choline