Comparison of the diagnostic efficacy of 68 Ga-FAPI-04 PET/MR and 18F-FDG PET/CT in patients with pancreatic cancer

Eur J Nucl Med Mol Imaging. 2022 Jul;49(8):2877-2888. doi: 10.1007/s00259-022-05729-5. Epub 2022 Mar 4.

Abstract

Purpose: We sought to assess the performance of 68 Ga-FAPI-04 PET/MR for the diagnosis of primary tumours as well as metastatic lesions in patients with pancreatic cancer and to compare the results with those of 18F-FDG PET/CT.

Methods: Prospectively, we evaluated 33 patients suspected to have pancreatic adenocarcinoma, of whom thirty-two were confirmed by histopathology, and one had autoimmune pancreatitis confirmed by needle biopsy and glucocorticoid treatment. Within 1 week, each patient underwent both 68 Ga-FAPI-04 PET/MR and 18F-FDG PET/CT. Comparisons of the detection abilities for primary tumours, lymph nodes, and metastases were conducted for the two imaging approaches. The original maximum standard uptake values (SUVmax) and normalised SUVmax (SUVmax/SUVbkgd) of paired lesions on 68 Ga-FAPI-04 PET/MR and 18F-FDG PET/CT were measured and compared.

Results: Thirty pancreatic cancer patients and three pancreatitis patients were enrolled. 68 Ga-FAPI-04 PET/MR and 18F-FDG PET/CT exhibited equivalent (100%) detection rates for primary tumours. The original/normalised SUVmax of primary tumours on 68 Ga-FAPI-04 PET was markedly higher than that on 18F-FDG (p < 0.05). Sixteen pancreatic cancer patients had pancreatic parenchymal uptake, whereas 18F-FDG PET images showed parenchymal uptake in only four patients (53.33% vs. 13.33%, p < 0.001). 68 Ga-FAPI-04 PET detected more positive lymph nodes than 18F-FDG PET (42 vs. 30, p < 0.001), while 18F-FDG PET was able to detect more liver metastases than 68 Ga-FAPI-04 (181 vs. 104, p < 0.001). In addition, multisequence MR imaging helped explain ten pancreatic cancers that could not be definitively revealed due to 68 Ga-FAPI-04 inflammatory uptake and identified more liver metastases than 18F-FDG (256 vs. 181, p < 0.001).

Conclusion: 68 Ga-FAPI-04 PET might be better than 18F-FDG PET in the detection of suspicious lymph node metastases. MR multiple sequence imaging of 68 Ga-FAPI-04 PET/MR was helpful for explaining pancreatic lesions in patients with obstructive inflammation and detecting tiny liver metastases.

Keywords: 18F-FDG; 68 Ga-FAPI-04; PET/CT; PET/MR; Pancreatic cancer.