This study investigated the pressures occurring within the arm human-machine-interfaces (HMI) of four different exoskeletons that support static and dynamic work at or above head level, and the effects of the HMI on neurovascular supply of the upper extremity using an orthopedic provocation maneuver with raised arms with and without the exoskeletons. Decreased time in the provocation maneuver with exoskeletons indicated a negative effect of the HMIs on the vascular and neural supply of the arm. Average pressure in the static situation was 3.2 ± 0.7 kPa and 4.4 ± 0.4 kPa with regular peak values of 6.5 ± 0.5 kPa in the dynamic task. These pressures were significantly higher than the pressure values that guarantee adequate tissue oxygenation. It remains unknown whether the way exoskeletons apply pressure affects vascular and neural supply to the arms, or whether the regular unloading during dynamic activity has a neutralizing effect.
Keywords: Circumferential compression; Overhead work; Physical human-machine-interface; Upper arm.
Copyright © 2022 The Authors. Published by Elsevier Ltd.. All rights reserved.