Under-correction of preoperative varus alignment does not lead to a difference in in-vivo bone loading in 3D-SPECT/CT compared to neutral alignment

Knee. 2022 Jan:34:259-269. doi: 10.1016/j.knee.2022.01.005. Epub 2022 Jan 22.

Abstract

Background: The aim was to investigate the correlation of bone tracer uptake (BTU) in SPECT/CT and changes in coronal knee alignment after total knee arthroplasty (TKA). We questioned if undercorrection of preoperative varus alignment leads to a difference in BTU compared to neutral alignment.

Methods: Consecutive 66 patients who received SPECT/CT before and after TKA were retrospectively included. Adjusted mechanical alignment was the alignment target. The alignment of the knee was measured on 3D-CT by selecting standardized landmarks. Maximum (mean ± SD) and relative BTU (ratio to the reference) were recorded using a previously validated localization scheme (p < 0.05).

Results: In the native group, 20 knees were aligned (30.3%) in valgus (HKA > 181.5°), 12 (18.2%) in neutral (178.5°-181.5°) and 34 (51.5%) in varus (HKA < 178°). Overall TKA changed the alignment towards neutral. 48.5% remained in the same groups, whereas 50% of native valgus and 33% of varus knees changed to neutral after TKA. In native varus alignment mean BTU was significantly higher in some medial tibial and femoral regions (fem1ia (p = 0.010), fem1ip (p = 0.002), tib1a.mid (p = 0.005), tib1a.tray (p = 0.000), tib1p.tray (p = 0.000)); in native valgus alignment mean BTU was higher in the corresponding lateral tibial and femoral regions (fem2ip (p = 0.001), tib2a.tray (p = 0.011), tib2p.tray (p = 0.002)). After TKA, a significant decrease in femoral and tibial BTU (femoral preoperative BTU 1.64 +/-0.69; femoral postoperative BTU 0.95 +/-0.42; p = 0.000// tibial preoperative BTU 1.65 +/- 0.93; tibial postoperative BTU 1.16 +/- 0.48; p = 0.000) and an increase in patellar BTU was observed (p = 0.025). Native varus alignment correlated with a higher medial BTU decrease medially. Undercorrection of preoperative varus alignment showed no higher BTU after TKA.

Conclusion: Preoperative varus alignment correlated with a higher decrease in BTU in specific femoral and tibial medial regions. Preoperative valgus alignment correlated with a higher decrease in the corresponding lateral regions. Undercorrection of preoperative varus alignment did not lead to higher bone loading reflected by BTU after TKA.

Keywords: Alignment; BTU; In-vivo bone loading; Knee; Neutral; SPECT/CT; TKA; Valgus; Varus.

MeSH terms

  • Arthroplasty, Replacement, Knee*
  • Humans
  • Knee Joint / diagnostic imaging
  • Knee Joint / surgery
  • Osteoarthritis, Knee* / surgery
  • Patella / surgery
  • Retrospective Studies
  • Single Photon Emission Computed Tomography Computed Tomography
  • Tibia / diagnostic imaging
  • Tibia / surgery