Visualization of initial bacterial colonization on dentin using fluorescence activating headlight for fluorescence enhanced theragnosis

Photodiagnosis Photodyn Ther. 2022 Jun:38:102732. doi: 10.1016/j.pdpdt.2022.102732. Epub 2022 Jan 20.

Abstract

Objective: To evaluate accuracy of caries detection and the application-sensitivity of the new Designs for Vision's REVEAL™ utilizing a fluorescence activating headlight for excitation purpose.

Materials and methods: REVEAL dental fluorescence loupes and headlight system were used. Occlusal enamel was removed, and mid-coronal dentine was exposed. Carious artificial lesion was created. Streptococcus mutans, Actinomyces naeslundii, and Streptococcus sanguis were used. The assessment was performed using two diagnostic methods: naked eye and Design for Vision Glasses with inter examiner blinding using two calibrated examiners. After 7 days, Raman measurements were made on dentin disc specimens with 785 nm wavelength. The bacterial counts in colony-forming units (CFU) were used to examine the growth kinetics of biofilms. The collagen fibril structure within the discs was performed using Transmission Electron Microscope. Scanning Electron Microscope was used to image samples at various magnifications. FISH was performed with specimens fixed in 4% paraformaldehyde in phosphate-buffered saline. Reproducibility was measured by Cohen kappa scores, values of which range from 0 for less than chance agreement to 1 for almost perfect agreement (p < 0.05).

Results: A significant kappa score of 0.706 showing significant reproducibility for the given diagnostic techniques, as all the teeth included in the study were spotted with the lesions. Most bacteria were detected using the CFU technique. The Raman bands scanned across the dentin surface at 960 cm-1 (P-O peak) are assigned to hydroxyapatite phosphate vibrations. FISH identified nearly all stained bacteria as days and time and dental hard tissue had a significant impact on the number of adherent bacteria. Scanning electron micrographs of polished cross sections of demineralized and non-demineralized specimens with perpendicular each tubule orientation (zone of demineralized dentin inset.

Conclusion: Fluorescent enhanced theragnosis through Reveal vision glasses can ensure constant monitoring and diagnosis of caries progress . This may allow for a better clinical outcome.

Keywords: Caries; REVEAL; REVEAL vision glasses; fluorescence; fluorescence detection.

MeSH terms

  • Dental Caries* / diagnosis
  • Dental Caries* / pathology
  • Dentin / microbiology
  • Fluorescence
  • Humans
  • Phosphates
  • Photochemotherapy* / methods
  • Reproducibility of Results
  • Streptococcus mutans

Substances

  • Phosphates